Hi Guys,
I'm getting the below warning when I'm trying to read the data from Teradata using Teradata Connector stage. Any idea on how to get rid of this warning?
When checking operator: When binding output interface field "SRC_ID" to field "SRC_ID": Implicit conversion from source type "ustring[max=20]" to result type "string[max=20]": Possible truncation of variable length ustring when converting to string using codepage UTF-8.
[Note: Title changed to be more descriptive - Andy]
Teradata warning: Implicit conversion from source type
Moderators: chulett, rschirm, roy
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
Teradata is using some kind of Unicode encoding (such as UTF-8). Your job is specifying VarChar(20) but is not specifying Unicode in the Extended column of the Columns grid.