Hi,
I created a simple job where I have two sources (defined as sequential file stages), a Join stage ( doing Outer joins) and then loading the final output to a sequential file stage.
Everything works fine. As I am using outer joins I am expecting null values. There is a record where null values should be appeared.
For Varchar fields the null value is appeared as blank. But the null value for Integer variable is appeared as '0' in the file.
Not sure why its coming like this. I am using all default settings for sequential file stage.
Please help me in this.
Null value appeared as '0' for integer column
Moderators: chulett, rschirm, roy
-
- Participant
- Posts: 21
- Joined: Tue Nov 02, 2010 2:36 pm
- Location: India
Null value appeared as '0' for integer column
Thank you,
Regards
Gowtham
(Learning DS)
Regards
Gowtham
(Learning DS)
-
- Premium Member
- Posts: 892
- Joined: Thu Oct 16, 2003 5:18 am
-
- Participant
- Posts: 21
- Joined: Tue Nov 02, 2010 2:36 pm
- Location: India
Hi,
Nope, No default value is set. Even I tried this option by manually setting it, its the same.
I believe that, this value is being set as 0 in Join stage. Is there any way we can debug and find out how the data is changing?
As its a parallel job there is no debug option. I am wondering how we can do this in this scenario.?
Thanks a lot!
Nope, No default value is set. Even I tried this option by manually setting it, its the same.
I believe that, this value is being set as 0 in Join stage. Is there any way we can debug and find out how the data is changing?
As its a parallel job there is no debug option. I am wondering how we can do this in this scenario.?
Thanks a lot!
Thank you,
Regards
Gowtham
(Learning DS)
Regards
Gowtham
(Learning DS)
That is the default behavior when going from a nullable input to a not nullable output and the input value is null.
Same in the lookup, merge etc...
Has nothing to do with your sequential stage.