Post questions here relative to DataStage Server Edition for such areas as Server job design, DS Basic, Routines, Job Sequences, etc.
Moderators: chulett , rschirm , roy
arnie_nits
Participant
Posts: 101 Joined: Mon Aug 13, 2007 2:32 am
Post
by arnie_nits » Mon Mar 22, 2010 6:58 am
Hi ,
I am unable to create copy of jobs.
Here is the error:
Error creating job CopyofABC to copy into
Error while creating job CopyofABC
Cannot open file RT_CONFIG10818
Please suggest.
Regards,
Arnie
Sreenivasulu
Premium Member
Posts: 892 Joined: Thu Oct 16, 2003 5:18 am
Post
by Sreenivasulu » Mon Mar 22, 2010 7:00 am
There is a patch available for this from IBM for 8.x. This happens for jobs having lot of transforms. No idea about 7.x.
Better check with IBM
Regards
Sreeni
chulett
Charter Member
Posts: 43085 Joined: Tue Nov 12, 2002 4:34 pm
Location: Denver, CO
Post
by chulett » Mon Mar 22, 2010 7:03 am
That error is specific to one particular job. Are you saying you can't make copies of
any jobs?
-craig
"You can never have too many knives" -- Logan Nine Fingers
arnie_nits
Participant
Posts: 101 Joined: Mon Aug 13, 2007 2:32 am
Post
by arnie_nits » Mon Mar 22, 2010 7:14 am
Yes.....I am unable to create copy of any job.
I guess this space issue.
I also got an error like:
ds_seqput: error in 'write()' - No space left on device.
Regards,
Arnab.
chulett
Charter Member
Posts: 43085 Joined: Tue Nov 12, 2002 4:34 pm
Location: Denver, CO
Post
by chulett » Mon Mar 22, 2010 7:30 am
I guess.
Solve that problem first and then we can clean up whatever else was screwed up because of it.
-craig
"You can never have too many knives" -- Logan Nine Fingers
ray.wurlod
Participant
Posts: 54607 Joined: Wed Oct 23, 2002 10:52 pm
Location: Sydney, Australia
Contact:
Post
by ray.wurlod » Mon Mar 22, 2010 1:30 pm
Once you've resolved the disk full issue, you might also like to check how many subdirectories exist in your project directory and whether your operating system as a limit on these.
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.