Hi all
I am getting this warning message and i don't know about "dfloat" can any one help me to remove this warning message. I have migrated this job from 7.5 version to 8.1 version it works fine in 7.5 version no warning messages but in 8.5 it shows the warning message.
Below is the warning message:
Aggregate_Count_of_Extracted: When checking operator: When binding output interface field "TER_CNT" to field "TER_CNT": Implicit conversion from source type "dfloat" to result type "int32": Possible range/precision limitation.
Conversion warning message
Moderators: chulett, rschirm, roy
Conversion warning message
Thanks
Naidu
Naidu
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
All calculation inside the Aggregator stage are performed as dfloat. Your design specifies an output column as integer data type. This generates the alert messages, because not all dfloat numbers can be stored as integer. Use the DecimalOutput property or Preserve Data Type property to avoid this alert.
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
-