Is there any way to avoid the refreshing of director for some times while running the job for a long time
-
- Participant
- Posts: 3337
- Joined: Mon Jan 17, 2005 4:49 am
- Location: United Kingdom
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
Close Director.
Minimizing Director comes close. But it's not as good as closing it.
Yes I'm serious. Every Director refresh is effectively a request back to the server to "stop what you're doing and give me an update". If Director is not running, these interruptions don't occur.
Minimizing Director comes close. But it's not as good as closing it.
Yes I'm serious. Every Director refresh is effectively a request back to the server to "stop what you're doing and give me an update". If Director is not running, these interruptions don't occur.
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Thank you. I searched the Documentation and it sais I have to set the variables using the DS Administrator. But I cannot find any of that variables there and if I try to add APT_MONITOR_TIME, I get an error message that sais "An environment variable of that name already exists". I also searched the systems environment variables. I have full access to the system. What can I do?
We are running Ascential DataStage 7.5 on Win 2003 Server.
We are running Ascential DataStage 7.5 on Win 2003 Server.
-
- Premium Member
- Posts: 1044
- Joined: Wed Sep 29, 2004 3:30 am
- Location: Nottingham, UK
- Contact:
Later versions of Director no longer have this check box, but you can still disable it in the registry. Open Notepad, save a file called "stoprefresh.reg" with this contents, and double-click it:JKenklies wrote:I'd like to turn the automatic refreshing off, but in tools>options i have only the possibility to set the interval to sth. between 2 and 65 seconds, but how can I disable it?
Code: Select all
Windows Registry Editor Version 5.00
[HKEY_CURRENT_USER\Software\Ascential Software\DataStage Client\Director]
"StopRefresh"="1"
You might need to pick a fight with your desktop support administrators if they've locked you down tighter than a duck's... er... feathers.
Last edited by PhilHibbs on Fri Apr 03, 2009 7:20 am, edited 1 time in total.
Phil Hibbs | Capgemini
Technical Consultant
Technical Consultant
Yes, we're fine with this discussion here. Questions about the client tools, Sequence jobs, generic DataStage questions and the like are all best placed here.
And now that I ponder it, all I can swear to is it still being there in 7.5.1a. I only had 7.5.2 installed for a few of days on a test Itanium server before they reclaimed the hardware so perhaps never noticed that option being gone.
And now that I ponder it, all I can swear to is it still being there in 7.5.1a. I only had 7.5.2 installed for a few of days on a test Itanium server before they reclaimed the hardware so perhaps never noticed that option being gone.
-craig
"You can never have too many knives" -- Logan Nine Fingers