I just replaced DB2 stage with teradata connector stage.
the job is running fine before with DB2 stage.
After replacing with connectoer stage it shows the following error
"main_program: Fatal Error: Transfer does not have this output interface as its destination. [api/interface.C:199]"[/b]
Does your job happen to contain a lookup? I have seen this error before when a lookup maps a key column from the reference link to the output link instead of from the main input link. Check with IBM support to see if there is a patch.
I had the same problem: "Transfer does not have this output interface as its destination".
Now there is an IBM patch: fix JR31099.
By waiting its implementation, i found a temporary workaround: our project was with 6 nodes, i modify to have only one.