Hi,
I am getting a warning when I looking up a flat with another flat file. The warning is "Lookup_24: When checking operator: Operator of type "APT_LUTCreateOp": will partition despite the
preserve-partitioning flag on the data set on input port 0.". Can anybody tell me how to eliminate it.
Thanks,
Look Up Warning
Moderators: chulett, rschirm, roy
-
- Premium Member
- Posts: 175
- Joined: Tue Oct 14, 2008 1:48 pm
Look Up Warning
Rajesh Kumar
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
You woul dhave had the answer faster had you bothered to Search DSXchange.
You need to clear the preserve partitioning flag from the upstream stage.
You need to clear the preserve partitioning flag from the upstream stage.
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
-
- Premium Member
- Posts: 175
- Joined: Tue Oct 14, 2008 1:48 pm
ray.wurlod wrote:You woul dhave had the answer faster had you bothered to Search DSXchange.
You need to clear the preserve partitioning flag from the upstream stage. ...
Yup got it I changed in all the stages except transformer. Now I changed in transformer also and then it worked. Thanks a lot
Rajesh Kumar