Friends, someone I could explain that this is wrong:
Transformer_1: Input dataset 0 has a partitioning method other than entire specified; disabling memory sharing.
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Transformer_1: Input dataset 0 has a partitioning method other than entire specified; disabling memory sharing.
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Last edited by igorbmartins on Sun Jul 20, 2008 8:45 am, edited 2 times in total.
-
- Charter Member
- Posts: 299
- Joined: Wed Nov 13, 2002 5:38 pm
- Location: USA
-
- Participant
- Posts: 161
- Joined: Mon Mar 17, 2008 10:33 am
Then I understood that I am not doing anything wrong in the JOB this is a failure of DSEE? Is it ?
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Last edited by igorbmartins on Sun Jul 20, 2008 8:43 am, edited 3 times in total.
-
- Charter Member
- Posts: 299
- Joined: Wed Nov 13, 2002 5:38 pm
- Location: USA
-
- Participant
- Posts: 161
- Joined: Mon Mar 17, 2008 10:33 am
So how can I do so that this message does not appear more? Can I disable (Message Handler)? I was in the Director and not seen where disable
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Last edited by igorbmartins on Sun Jul 20, 2008 8:42 am, edited 1 time in total.
-
- Participant
- Posts: 161
- Joined: Mon Mar 17, 2008 10:33 am
So how can I do so that this message does not appear more? Can I disable (Message Handler)? I was in the Director and not seen where disable
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Igor Bastos Martins
http://www.oportunidadesembi.com.br
Last edited by igorbmartins on Sun Jul 20, 2008 8:45 am, edited 1 time in total.
-
- Charter Member
- Posts: 299
- Joined: Wed Nov 13, 2002 5:38 pm
- Location: USA
-
- Participant
- Posts: 161
- Joined: Mon Mar 17, 2008 10:33 am
Friends now work,
1. I was in DataStage Director
2. Clicked with the right button on the log WARNING
3. I clicked "Add to rule message hander."
4. I was in DataStage Administrator;
5. Entered in the project;
6. I went to the tab Parallel;
7. In Message Handler for Parallel JOBs I selected "TFCP000043."
8. Ready now it's not the most WARNIG, only warns in the log that has a message handle.
Even having resolved someone knows where I can a path from IBM to fix these WARNIGs?
Thanks
1. I was in DataStage Director
2. Clicked with the right button on the log WARNING
3. I clicked "Add to rule message hander."
4. I was in DataStage Administrator;
5. Entered in the project;
6. I went to the tab Parallel;
7. In Message Handler for Parallel JOBs I selected "TFCP000043."
8. Ready now it's not the most WARNIG, only warns in the log that has a message handle.
Even having resolved someone knows where I can a path from IBM to fix these WARNIGs?