Hi everybody,
I'm having problems by using job parameter in NLS Map box in a sequential stage. (DS EE r. 7.5.1.A)
If I click 'View Data' by editing the project default as the parameter value, I get this:
FATAL ERROR (APT_CharsetConverterRep::initConv()): #JobParameter# is not a valid codepage.
This problem does not cause a runtime abort, but I need to test my development jobs, first.
Any suggestion?
Problems with NLS map in sequential stage
Moderators: chulett, rschirm, roy
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
The problem seems to appear by using ISO-8859-1 Code Page (that is my project default) as job parameter value.shails wrote:What is the Job Parameter value you are using for NLS? What is the project default character set?
By using ISO-8859-2 Code Page (with the appropriate file), I can have data preview, without any problem.
Ray, take a look to NLS tab in a (parallel) input sequential stage (DS 7.5.R.1A).