Ok... where in the heck does one change the default 'Abort job after X Warnings' limit in the Designer? I hate the fact that it defaults to Unlimited and it keeps becoming an issue because people don't seem to remember it works that way.
The 'Tools/Options' setting for the Director only works for jobs run from the Director. There's no equivalent setting I've ever found in any of the other tools at any level. Is there perhaps a registry hack we can use to set that or are we stuck with it defaulting to Unlimited forever?
-craig
"You can never have too many knives" -- Logan Nine Fingers
The default default (ibid?) on version 7.0 is 50. Just checked. I'll have to wait till I get to a 7.5 system to verify your assertion.
As to where it's set elsewhere, it wouldn't be a Registry hack if it were going to control dsjob - which can be, and usually is, executed on the server. Most of my scripts explictly specify -warn 2 or thereabouts in any case, since very few (if any) of my jobs generate warnings other than genuine ones.
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Right... from a job control or scripted standpoint, I'm good. Warning limits are throttled down appropriately and I can handle the default of 50 from the Director. Specifically wondering how to change the seeming default of Unlimited warnings to something more... limiting... when running a job from the Designer.
-craig
"You can never have too many knives" -- Logan Nine Fingers
When you run the job in designer you get a Job run Options pop up in that there is are four tabs Parameters,Limit,Tracing and General. You can change the warning limit here. I hope thats helps.
Correct. Unfortunately, most people won't bother to switch tabs and constantly run jobs with the default value... hence the desire to change the default.
-craig
"You can never have too many knives" -- Logan Nine Fingers
I guess the question is why running from Designer doesn't pick up the defaults specified in Director. Have you asked this over on ADN, or of your support provider?
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
No... figured I'd start where I stood the best chance of getting an answer. Ah, well. Monday [crosses fingers] we'll be on 7.5.1A and I'll check if the behaviour is any different once we're upgraded and if not, ping Ascential.
-craig
"You can never have too many knives" -- Logan Nine Fingers
We are using Data Stage 7.5, Data Stage Client is installed in 5 PC's, Intially during the development of the job default limit is 50. One of my collegue was changed it to Unlimited. In the Data Stage Director in my pc (except the pc of my collegue who changed), the default is still 50 for that job. Whereas if we run, it was running good for more than 50 warnings. I guess it is a bug in Data Stage. Please clarify.