Error Msg- Cleanup after ABORT raised in stage
Moderators: chulett, rschirm, roy
Error Msg- Cleanup after ABORT raised in stage
Hi,
Any idea how to troubleshoot the DS jobs if getting following error:-
DataStage Job 1051 Phantom 2051
Program "DSD.IPCOpen": Line 185, WRITE failure.
Attempting to Cleanup after ABORT raised in stage SMSCERRORLoadFactMetricaSmsError..Link_Collector
DataStage Phantom Aborting with @ABORT.CODE = 3
Regards,
SC
Any idea how to troubleshoot the DS jobs if getting following error:-
DataStage Job 1051 Phantom 2051
Program "DSD.IPCOpen": Line 185, WRITE failure.
Attempting to Cleanup after ABORT raised in stage SMSCERRORLoadFactMetricaSmsError..Link_Collector
DataStage Phantom Aborting with @ABORT.CODE = 3
Regards,
SC
Do a job reset and look into the new message(s) in the log file, often they contain additional information.
<a href=http://www.worldcommunitygrid.org/team/ ... TZ9H4CGVP1 target="WCGWin">
</a>
</a>
Huh? Maybe in a PX job, but not in Server anywhere that I recall.kumar_s wrote:u can find this in the output stage, under properties tab -->Opiton ---> Clean On Failure
The best thing to try is what Arnd suggested - reset the job after it aborts via the Director and see if any messages come into the log labelled as 'From previous run...'.
-craig
"You can never have too many knives" -- Logan Nine Fingers
"You can never have too many knives" -- Logan Nine Fingers
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
Attempting to cleanup after abort is purely informational, and can be noted and ignored.
The actual error has occured in a Link Collector stage, and is a failure to write - presumably to a buffer used by that stage or to a file (Sequential File stage?) connected to its output. This is most likely to be a permissions or space problem.
Reset the job in Director; there may be a "from previous run..." message logged that contains additional diagnostic information.
Also, determine the name of the directory referred to in your UVTEMP configuration parameter, and check that its file system has plenty of free space.
The actual error has occured in a Link Collector stage, and is a failure to write - presumably to a buffer used by that stage or to a file (Sequential File stage?) connected to its output. This is most likely to be a permissions or space problem.
Reset the job in Director; there may be a "from previous run..." message logged that contains additional diagnostic information.
Also, determine the name of the directory referred to in your UVTEMP configuration parameter, and check that its file system has plenty of free space.
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Hi Ray,
Yes. My job is job server.
10x! That job can be reset and re-run successfully.
"determine the name of the directory referred to in your UVTEMP configuration parameter, and check that its file system has plenty of free space. "
Would like to what do u means by "determine the name of the directory referred to in your UVTEMP configuration parameter"? The name of the directory in where?
Regards,
SC
Yes. My job is job server.
10x! That job can be reset and re-run successfully.
"determine the name of the directory referred to in your UVTEMP configuration parameter, and check that its file system has plenty of free space. "
Would like to what do u means by "determine the name of the directory referred to in your UVTEMP configuration parameter"? The name of the directory in where?
Regards,
SC
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
In the DataStage home directory is a file called uvconfig containing a heap of DataStage configuration parameters. UVTEMP is one of these. Its value is a directory used for various kinds of temporary file by the DataStage run machine.
From the operating system you can execute a command such as
From the operating system you can execute a command such as
Code: Select all
`cat /.dshome`/bin/analyze.shm -t | grep UVTEMP
IBM Software Services Group
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.
Any contribution to this forum is my own opinion and does not necessarily reflect any position that IBM may hold.