We are implementing the Peoplesoft Warehouse module, We are working on the ETL jobs deleivered by Accential, One of the job fails and it comes back with this error message,
From previous run
DataStage Job 2002 Phantom 20571
jobnotify: Error 904 occurred.
DataStage Phantom Finished.
[741508] Done : DSD.StageRun FDM84_88_BUS_UNIT_TBL_PM. FDM84_88_BUS_UNIT_TBL_PM.exp_LASTUPDDTTM_RUN_HST 1 0/0
[737516] DSD.StageRun FDM84_88_BUS_UNIT_TBL_PM. FDM84_88_BUS_UNIT_TBL_PM.exp_EMPTY_STRING_FDM 1 0/0 - terminated.
Thanks
ash
Error 904 Occured
Moderators: chulett, rschirm, roy
-
- Participant
- Posts: 54607
- Joined: Wed Oct 23, 2002 10:52 pm
- Location: Sydney, Australia
- Contact:
Welcome aboard! :D
There's not really much information here. Were there any other warnings in the log for this job? What I can see is that you have a job with two Transformer stages, and the one called FDM84_88_BUS_UNIT_TBL_PM.exp_EMPTY_STRING_FDM had a problem.
But without other error messages, this is quite difficult to diagnose further.
There's not really much information here. Were there any other warnings in the log for this job? What I can see is that you have a job with two Transformer stages, and the one called FDM84_88_BUS_UNIT_TBL_PM.exp_EMPTY_STRING_FDM had a problem.
But without other error messages, this is quite difficult to diagnose further.
IBM Software Services Group