Search found 26 matches
- Tue Feb 15, 2011 12:42 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Load same teradata table 2 times in a single job
- Replies: 21
- Views: 10727
- Sun May 24, 2009 10:50 pm
- Forum: Information Analyzer (formerly ProfileStage)
- Topic: IA - ANALYZERPROJECT didnot get created during install
- Replies: 5
- Views: 4106
- Wed May 20, 2009 6:56 am
- Forum: Information Analyzer (formerly ProfileStage)
- Topic: IA - ANALYZERPROJECT didnot get created during install
- Replies: 5
- Views: 4106
IA - ANALYZERPROJECT didnot get created during install
Post 8.1 install, we were not able to see the ANALYZERPROJECT created.
And we tried to do the IA - Analysis Database - Analysis ODBC DSN - Validate Engine Connection, we got error per Error executing DS Job.
Have you encountered the similar issue ?
Any suggestion to rectify the issue ?
And we tried to do the IA - Analysis Database - Analysis ODBC DSN - Validate Engine Connection, we got error per Error executing DS Job.
Have you encountered the similar issue ?
Any suggestion to rectify the issue ?
- Mon Jan 19, 2009 12:58 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Surrogate Key Generator - produced sequence num with a gap
- Replies: 2
- Views: 1934
- Mon Jan 19, 2009 11:08 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Surrogate Key Generator - produced sequence num with a gap
- Replies: 2
- Views: 1934
Surrogate Key Generator - produced sequence num with a gap
Kind of wonder if you had experienced the similar issue - Surrogate Key Generator produced sequence number with a gap. Backgrouund info: =========== (1) the state file is deleted and created every time before the job is run (2) expect the Surrogate key number start from 1 and increment by 1 (3) Job ...
- Fri Jun 15, 2007 3:54 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Size/Capacity of a DataStage EE on Window platform
- Replies: 0
- Views: 839
Size/Capacity of a DataStage EE on Window platform
If you are running DataStage EE (7.5x2)on Window platform, would you mind to share information about the Size/Capacity of your production DataStage EE Server ? For example, number of CPU, size of RAM, size of scratch disk pool, size of sort disk pool, average workload in terms of DataStage jobs, any...
- Fri Sep 29, 2006 3:55 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Lookup failure
- Replies: 4
- Views: 3519
- Wed May 31, 2006 9:24 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: multiload utility in Parallel mode
- Replies: 16
- Views: 11384
Hi there, Just came to this discussion and would like to re-confirm below: 1. Change the Execution mode of Multiload stage to Sequential mode. Is this true or in other words, Sequential mode is the only execution mode when using Teradata MultiLoad stage in EE ? If wish to execute in Parallel mode, t...
- Tue Apr 18, 2006 8:58 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Teradata Mload/Fastexport stage error
- Replies: 8
- Views: 6842
- Tue Apr 18, 2006 8:47 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: HandleNull
- Replies: 12
- Views: 5691
Yes, you are correct about the target column needing to be a NON-null value. My question is more about Null handling for a DATE type column. Attempted to use Null handling around the input column, but for example: NullToEmpty ==> compile time error NullToValue( InDate, '1900-01-01' ) ==> No good eit...
- Sun Apr 16, 2006 4:04 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: HandleNull
- Replies: 12
- Views: 5691
- Sun Apr 16, 2006 2:45 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: HandleNull
- Replies: 12
- Views: 5691
Hi Ray, Yes, the input column was qualified with the link name. The example was just a short-hand typing to illustrate the issue. IF IsNull( SrcInputData.LAST_SNAP_DT ) Then SetNull() Else SrcInputData.LAST_SNAP_DT Is this what you meant ? This transformation works for DataSet except Sequential file...
- Sat Apr 15, 2006 8:33 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: HandleNull
- Replies: 12
- Views: 5691
DataStage EE 7.5x2 Server OS: Window 2003 For Null Handling, how are you tackling DATE ? When the Input and Output column is delcared as DATE type, is having trouble to use the available NULL Handling function on dealing with Null date column from input and mapping to an output column. The input dat...
- Wed Sep 17, 2003 11:08 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Im confused
- Replies: 30
- Views: 8951
- Wed Jul 30, 2003 10:51 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Read config/sequence from database
- Replies: 20
- Views: 6133