Search found 200 matches
- Wed Aug 20, 2003 6:19 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: why use Datastage
- Replies: 18
- Views: 2907
Whoa! Circle the wagons! I would offer the following points; 1. You are using SQL Server 2. DTS is FREE 3. You are doing text file ETL. This is not heavy ETL lifting. DTS has a GUI paradigm, can be scheduled, has metadata capability, is based on a industry accepted modern Programming language (that ...
- Tue Aug 19, 2003 11:10 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: why use Datastage
- Replies: 18
- Views: 2907
- Sat Jul 26, 2003 3:13 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: XML Parsing within Basic Code
- Replies: 3
- Views: 1514
Writing to a sequential file would be extraneous since I still have to parse the XML to eliminate the unique elements like timestamps. Also I forgot to mention that the order of the XML elements is not always the same. Using the XML Input stage is a poor option since every job would require a unique...
- Mon Jun 30, 2003 3:01 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: XML Input Stage Warning
- Replies: 0
- Views: 653
XML Input Stage Warning
I am getting the following informational warning for every message parsed by the XMLInput stage (v2.0.0); Xalan fatal error (publicId: , systemId: , line: 1, column: 1): The main XML document cannot be empty The XML appears to be parsed correctly and processing continues normally. With other message...
- Fri Jun 27, 2003 12:45 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Function in user defined SQL
- Replies: 8
- Views: 3753
I've never been able to import a Stored Procedure either but then the whole Oracle table Definition import is not good anyway (synonynms) so it's par for the course. You can, of course, manually type in the stored procedure. I think this thread has gotten outta hand. Use the function call to dual si...
- Mon Jun 23, 2003 6:15 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Global variable
- Replies: 19
- Views: 5499
- Sun Jun 22, 2003 8:19 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Global variable
- Replies: 19
- Views: 5499
How do I format the oconv for milliseconds? The Help examples are only to the second. I'm told by Ascential that DataStage 5.2.1 on HP-UX 11.11, which is our system, cannot support milliseconds without a patch. This illustrates Ascential's overall shortcoming with designing a realtime architecture. ...
- Fri Jun 20, 2003 2:40 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Global variable
- Replies: 19
- Views: 5499
- Fri Jun 20, 2003 11:25 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Global variable
- Replies: 19
- Views: 5499
There is a need to balance the impact on the design and function of any of our DataStage jobs. I do not want to intermingle the performance functionality with the ETL functionality. The method I am seeking is a single stage variable in every transformer of a DS job. This unobtrusive stage variable c...
- Thu Jun 19, 2003 12:58 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Global variable
- Replies: 19
- Views: 5499
I am using 5.2.1. As an example, I am trying to build the following string within the derivation of a stage varaible; @USER0:'':time():''. I'm not worried about spanning processes. I would be quite happy if I were able to assign USER0 a value in one stage variable of a transformer and retreive it in...
- Thu Jun 19, 2003 11:07 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Oracle Advanced Queue
- Replies: 9
- Views: 3489
Sorry, I tried to say two things with one sentence. My jobs use MQSeries as a source of data. The MqSeries stage has a wait time defined as -1 which means its realtime. The shutdown mechanism is triggered when a MQ Message of a user defined type arrives on the source queue. Some of my jobs target Or...
- Wed Jun 18, 2003 1:51 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Global variable
- Replies: 19
- Views: 5499
- Wed Jun 18, 2003 1:36 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Oracle Advanced Queue
- Replies: 9
- Views: 3489
- Wed Mar 19, 2003 3:40 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: can find repository pane
- Replies: 4
- Views: 785
Losing a Pane from Designer client User Interface Once the Designer UI on the client has been customized, it then becomes possible to lose a pane. To regain it; 1. Run regedit 2. HKEY_CURRENT_USER =>Software =>Ascential Software 3. Delete the folder (and consequently all sub-folders) DSDesign. This ...
- Wed Mar 12, 2003 9:37 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: DataStage Certification Information
- Replies: 9
- Views: 2866
Here's an interesting e-mail I received a about a year ago. I pursued it with Ascential but didn't get anywhere. Perhaps others will have better luck. I think it is defunct. Subject: New Ascential Certification Professional Program Ascential Certified Professional Program is now active and ready for...