Search found 19 matches
- Thu Jul 13, 2006 2:16 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: What is the Difference between Active and Passive Stage
- Replies: 11
- Views: 6178
Thanks, This message board used to be free...?? Only this one time, actually for less than 14 cents a day you can become a premium member and get access to the ocean of knowledge. Highly advisable. The definition of a passive stage for your purposes is one that reads from a source or writes to a tar...
- Thu Jul 13, 2006 2:06 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: What is the Difference between Active and Passive Stage
- Replies: 11
- Views: 6178
I cannot read AarndW's messgae as I am a standard member...can you tell me what he said.
All I want to know the fundamental differcence between active and passive stage.
All I want to know the fundamental differcence between active and passive stage.
DSguru2B wrote:Check out ArndW's reply in the following post
viewtopic.php?t=97052
- Thu Jul 13, 2006 1:56 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: What is the Difference between Active and Passive Stage
- Replies: 11
- Views: 6178
- Sun Feb 12, 2006 11:30 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Run Time Column Propogation Issue.
- Replies: 9
- Views: 5259
- Sat Feb 11, 2006 11:21 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Run Time Column Propogation Issue.
- Replies: 9
- Views: 5259
Hi, How about, if your mannually take off the unicode option for varchar field. You can also try to remove from dsx as a whole if the above doesnt works. Out of curiosity, what makes your job to break if unicode present? -Kumar Kumar, We since I am using Run Time Column propogation and not manually...
- Fri Feb 10, 2006 8:19 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Run Time Column Propogation Issue.
- Replies: 9
- Views: 5259
Hi You can disable this by using Datastage Administrator. Logon to the project where you want to disable. Inside that untick the Enable Runtime Column Propagation for Parallel Jobs Regards Hi I think I was not that clear. What I ment is that in my Job design I want run time column propogation. Howe...
- Thu Feb 09, 2006 2:05 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Run Time Column Propogation Issue.
- Replies: 9
- Views: 5259
Run Time Column Propogation Issue.
In my Job design I am using run time column propogation. The job design is simple...But it uses "Run Time Column Propogation" Job design : Table_A ---> Transformer ----> Table_B The metadata of the tables A and B are DLV_DT VARCHAR2(8 BYTE), FRQ VARCHAR2(3 BYTE), PCS_DT VARCHAR2(8 BYTE), M...
- Thu Feb 09, 2006 1:58 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ORCHESTRATE exception in main program: APT_ParseError
- Replies: 17
- Views: 11649
Your image quota has been exceeded and you still haven't found out what schema values DS is using. Someone more knowledgeable than I will certainly help you. It might still behoove you to find your orchadmin command - if not for this issue then for the future. I think I got it running... it was an ...
- Tue Feb 07, 2006 3:39 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ORCHESTRATE exception in main program: APT_ParseError
- Replies: 17
- Views: 11649
Can you paste the snapshot of the column definition as defined in your oracle stage Arvind, I look through your suggestion.. and it seems that the medata matches and the Nullabe are set to YES Attached is the ling to the image of my job http://us.share.geocities.com/kapil_ladha/meta.bmp ( If the im...
- Tue Feb 07, 2006 3:24 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ORCHESTRATE exception in main program: APT_ParseError
- Replies: 17
- Views: 11649
Kapil - I give up. We are not trying to hide a solution from you and you don't need to restate your query. If someone could answer your question with the data listed so far they would have. You are getting a schema error. You need to list the schema the way DataStage sees it. Orchadmin will do that...
- Tue Feb 07, 2006 3:02 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ORCHESTRATE exception in main program: APT_ParseError
- Replies: 17
- Views: 11649
- Tue Feb 07, 2006 2:45 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ORCHESTRATE exception in main program: APT_ParseError
- Replies: 17
- Views: 11649
- Tue Feb 07, 2006 1:14 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ORCHESTRATE exception in main program: APT_ParseError
- Replies: 17
- Views: 11649
Hi, What is the stage you use in the job for input. Are you doing any type conversion. Using any transformer? Is there any field length been unhaldled or empty? Have you given any varchar or char type of field as feild length as 0? What type of data is it? -Kumar Hi Kumar, I am doing a simple movin...
- Mon Feb 06, 2006 3:10 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ORCHESTRATE exception in main program: APT_ParseError
- Replies: 17
- Views: 11649
ORCHESTRATE exception in main program: APT_ParseError
hi guys, when i run a px job the job abborts with the following message : - main_program: Fatal Error: Caught ORCHESTRATE exception in main program: APT_ParseError: Parsing parameters "max=0" for schema type "ustring": Max length must be positive, got: "0" Could not fin...
- Sat Nov 26, 2005 8:11 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Change Capture and Change Apply Satage in Datastage
- Replies: 7
- Views: 10327