Hi khaja,
Check this link and let me know, if you get the result.
viewtopic.php?p=166832&highlight=#16683 ... ds
Nagesh.
Search found 218 matches
- Wed Oct 11, 2006 6:50 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Modify Stage---Hw to Trim A field
- Replies: 2
- Views: 1096
- Wed Oct 11, 2006 6:26 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Problem while using stage variables
- Replies: 9
- Views: 4468
Hi Deep, As I remember, stage variables required not null values. Becuase, there is no concept of of Null/Not null for Stage variables. I am not sure whether stage variable can hold nulls or not ? Just try out u r setting of Null at the derivation level of Column. May be it will help you. Regards Na...
- Mon Oct 09, 2006 2:43 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DB2/EE Stage load failure
- Replies: 4
- Views: 2081
Hi Chuah, Presently, in your job config file is set for 4 nodes. But, your output database is set for single partition. Problem is your Dataset is created for 4 nodes and it is trying to load the data in a single node constraint partition database. To get out of this problem we can do one thing, jus...
- Tue Sep 26, 2006 9:31 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sub Sequence will improve performance
- Replies: 9
- Views: 5960
pneumalin, Thanks for your response. I have tried by changing the default value of Environmental Variable APT_MONITOR_SIZE from blank to 100000. But, it's not completely solved my problem. Then I have set the environmental variable APT_NO_JOB_MON to true. Now, my sequence is succesfully completed wi...
- Fri Sep 22, 2006 5:19 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sub Sequence will improve performance
- Replies: 9
- Views: 5960
Thanks Nitin for your response. Hi All, After Split up of my big sequence in to two sequences, still I am facing the same problem. It's working in Dev and aborting in SYS and OAT for somany times with Unix SIG kill and running after some runs .Can I split those sequences again in to two more sequenc...
- Thu Sep 21, 2006 9:41 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sub Sequence will improve performance
- Replies: 9
- Views: 5960
- Wed Sep 20, 2006 8:13 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sub Sequence will improve performance
- Replies: 9
- Views: 5960
Arnd, Thanks for your reply. I have tried to Identify the problem. IBut, the main thing is the same sequence is working finely in Dev. But, its failing in SYS and UAT. got the following abort message for all my aborting jobs. node_node1: Player 12 terminated unexpectedly. Fatal Error: waitForWriteSi...
- Wed Sep 20, 2006 7:51 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sub Sequence will improve performance
- Replies: 9
- Views: 5960
Sub Sequence will improve performance
Hi Folks, My sequence is getting aborted some times and succesfully completed some times. I have nearly 30 Jobs in my sequence. In that 10 jobs have big derivations. Some times Derivation 1 failing and some times Derivation 1 will run succesfully, but Deriavtion 2 failing. Some times sequence comple...
- Thu Sep 14, 2006 6:32 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Parallel lookup stage in V 7.5.1
- Replies: 4
- Views: 1661
Hi lstsaur, I have tried to perform TrimLeadingTrailing to my inputcolumn in the key expression and I have tried to put hard code value in the key expression to perform lookup and I have tried to use substring function to my inputcolumn in key expression. In all above cases my job was aborted. More ...
- Wed Sep 13, 2006 9:06 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Parallel lookup stage in V 7.5.1
- Replies: 4
- Views: 1661
- Wed Sep 13, 2006 8:01 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Parallel lookup stage in V 7.5.1
- Replies: 4
- Views: 1661
Parallel lookup stage in V 7.5.1
Hi Folks, I have this question from a long time. Now, I am able to ask about lookup stage in v 7.5.1. One thing I am observed is the Key Expression editor of lookup. When I tried to put some expression their in the key expression editor, It's simply aborting the job. I have tried by giving the param...
- Thu Jun 22, 2006 3:51 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Problem with APT_STRING_PADCHAR
- Replies: 9
- Views: 5743
$APT_STRING_PADCHAR issue
The problem with regards to $APT_STRING_PADCHAR is coming in specific project. In development project the sequence using this parameter works fine. However, in the sys test project the sequence is giving problem. Is there any other enviornment variable which is dependent on $APT_STRING_PADCHAR or is...
- Thu Jun 22, 2006 2:26 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Problem with APT_STRING_PADCHAR
- Replies: 9
- Views: 5743
Re: Problem with APT_STRING_PADCHAR
Arnd, Thanks for your reply. My problem is the APT_STRING_PADCHAR is affecting the jobs, which don't have DB2 EE Stages. My Job flow : first Job DB2 API STAGE .................. Dataset Second Job DATASET ( this one from First Job).............. FILTER .................. DATASET So, the above two jo...
- Wed Jun 21, 2006 10:53 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Problem with APT_STRING_PADCHAR
- Replies: 9
- Views: 5743
Problem with APT_STRING_PADCHAR
Hi Folks, I am facing a strange problem with $APT_STRING_PADCHAR. I am using this varible for my DB2 EE Load job. It's working fine for my Load job. But, the problem is , when i Tried to set this variable in the sequence. This variable is affecting the other jobs(which don't have $APT_STRING_PADCHAR...
- Thu Apr 20, 2006 7:07 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Strange Warning in DB2 EE Stage
- Replies: 3
- Views: 2258
Strange Warning in DB2 EE Stage
Hi All, I am facing the following warning in DB2 EE stage db2HEW_CHANL_USAGE_SUMMins: The environment variable DB2INSTANCE is currently set to `db2inst1' and is being changed to `ihewd01' as specified in the server option; if this instance is a different version of DB2, the program may not succeed. ...