Search found 336 matches
- Fri Apr 06, 2007 6:01 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Real Time
- Replies: 2
- Views: 1395
Thanks for the info. The problem I am facing is, I have never used this stage and I was hoping to see some examples on how it is used. We have a requirement for messaging and I must learn how to implement it. The docs are geared towards an experienced user. You are probably right that we didn't inst...
- Thu Apr 05, 2007 1:28 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Real Time
- Replies: 2
- Views: 1395
Real Time
Has anyone used the MQ plug-in and could someone please direct me to a place where there may be some examples or documentation. I have looked through the MQ Series Connectivity docs but they are very vague. During our version 8.0 installation, we installed the client software. We are getting a MQSCO...
- Tue Apr 03, 2007 11:28 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ds_loadlibrary Problem
- Replies: 2
- Views: 1812
ds_loadlibrary Problem
I found this error in the Server Forum. We are receiving the following in the PX version
"ds_loadlibrary: Win32 error in LoadLibrary of mqs.dll - the specified module could not be found"
Has anyone ever received this message and how did you resolve.
Thanks
"ds_loadlibrary: Win32 error in LoadLibrary of mqs.dll - the specified module could not be found"
Has anyone ever received this message and how did you resolve.
Thanks
- Tue Apr 03, 2007 11:26 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: ds_loadlibrary Error
- Replies: 4
- Views: 2615
- Tue Apr 03, 2007 11:24 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: ds_loadlibrary Error
- Replies: 4
- Views: 2615
- Wed Mar 28, 2007 2:19 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Migration 7.5x2 to 8.0
- Replies: 15
- Views: 4526
Hi all, Here's an update on my current situation. The jobs that worked in 7.5x2 and not in 8.0 has been defined as a partitioning error. The job will work using 1 or 2 nodes. Sometimes they work with 3. As soon as we change the configuration to 4 or more, the jobs abort. The issue is in IBM tech sup...
- Fri Mar 23, 2007 8:00 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Datastage EE with windows
- Replies: 20
- Views: 10855
- Fri Mar 23, 2007 6:54 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Datastage EE with windows
- Replies: 20
- Views: 10855
- Thu Mar 22, 2007 7:48 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Migration 7.5x2 to 8.0
- Replies: 15
- Views: 4526
More information on the issue. I have been dissecting the job into smaller chunks to help debug the problem. I have narrowed it down to the following. Within the job there are two joins and 5 aggregate stages. If I remove the final join and created two datasets, the job runs fine. As soon as I put t...
- Tue Mar 20, 2007 12:20 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Migration 7.5x2 to 8.0
- Replies: 15
- Views: 4526
We do not have a firewall and during the installation, we deferred to the installation defaults. We are running a 8 node Windows servers with plenty of memory. We are opening up tickets with IBM in order to solve this issue. After reading through the information, we are still unclear on what is caus...
- Mon Mar 19, 2007 1:31 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Runtime Error
- Replies: 4
- Views: 2313
Runtime Error
We are running this job in Version 8.0 I received the following error during runtime. The job never got off the ground. I received this message immediately. main_program: Internal Error: (APT_SC::downcast(pConsumer())->kind() == APT_Operator::eParallel): sc\sc.C: 3936 Does anyone have any ideas what...
- Mon Mar 19, 2007 11:18 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Migration 7.5x2 to 8.0
- Replies: 15
- Views: 4526
This is the following error I receive from the job. Here's a brief overview of what I have attempted to determine the problem. I took the job that keeps aborting and started removing stages to see if I could narrow down the problem. What is left is, two aggregators stream being joined into one datas...
- Fri Mar 16, 2007 6:30 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Migration 7.5x2 to 8.0
- Replies: 15
- Views: 4526
Migration 7.5x2 to 8.0
We migrated to the new version of Datastage and received a few issues that we can't seem to resolve. 1. After the migration, none of our DS datasets that we created in 7.5 could be found or read by 8.0. Is there a migration routine for datasets? 2. Smaller jobs consisting of 5 to 10 stages work fine...
- Thu Mar 15, 2007 1:08 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DB2 Abort
- Replies: 4
- Views: 1394
- Thu Mar 15, 2007 1:06 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Key Partition Incremental
- Replies: 4
- Views: 1267
More information from my inquiry. I was wrong in my explanation. After reviewing the partitions, I realized that the Stage variable are not getting reset, they are starting at 1 for each partition. After discussing this further with a DB2 expert, it will be very difficult to implement a restart mech...