Search found 15 matches

by urs_ravindra
Sat Apr 08, 2006 3:36 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Hash file look up not working
Replies: 10
Views: 4337

Hash file look up not working

Hi Dudes, The following is the flow in my job. `````````````````Hash File(Having row count in seq file) ``````````````````````| ``````````````````````| ``````````````````````V Seq File-----------> Transformer------------->Seq File I want to load all the rows into target file excluding first and last...
by urs_ravindra
Thu Mar 02, 2006 11:03 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Regarding Sequencer job
Replies: 2
Views: 1514

Regarding Sequencer job

when i run the controljob of sequencer,it finished with 1 warning.

The only job aborted is running fine when i ran it separately.

what should be the reason?
by urs_ravindra
Thu Mar 02, 2006 10:34 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Regarding Abnormal termination of stage
Replies: 1
Views: 1036

Regarding Abnormal termination of stage

I am getting error as "Abnormal termination of stage" while running the job.
by urs_ravindra
Fri Jan 27, 2006 8:57 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: At row 2000, link "DSLink6"
Replies: 10
Views: 4099

I Mean to say, we ran the job in director. The problem is not because of any client system. From the same system the jobs ran withtout this problem. Very rarely we get this problem.
by urs_ravindra
Fri Jan 27, 2006 8:02 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: At row 2000, link "DSLink6"
Replies: 10
Views: 4099

1)We trigger it from DataStage director. 2)We don't trigger it from command prompt. 3)We always use administrator account to run the jobs. 4)But very rarely we are getting this problem and max 2000 rows are processed in the jobs. 5)In the log, Generally it shows 0/50 as row/warning limit. Very rarel...
by urs_ravindra
Fri Jan 27, 2006 7:23 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: At row 2000, link "DSLink6"
Replies: 10
Views: 4099

We didn't specify any row limit and running the jobs from director.
But still it is getting stopped after 2000 rows. This is happening very rarely, but since it is happening in production, there is huge impact.

Please let me know root cause for this and how to avoid this.
by urs_ravindra
Fri Jan 27, 2006 4:51 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Problem with Sequencer
Replies: 1
Views: 1309

Problem with Sequencer

Hi, We are using DS 7.0 server Edition. Some times we are getting the entry in the log "At row 2000, link 'DSLink6' Run Stopped". It is not showing this as an error/warning. Jobs process 2000 rows ans stop processing after that. We checked the log of sequencer, it has called the jobs with ...
by urs_ravindra
Fri Jan 27, 2006 4:33 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: At row 2000, link "DSLink6"
Replies: 10
Views: 4099

At row 2000, link "DSLink6" Run Stopped

Small correction to the subject

At row 2000, link "DSLink6" Run Stopped
by urs_ravindra
Fri Jan 27, 2006 4:31 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: At row 2000, link "DSLink6"
Replies: 10
Views: 4099

At row 2000, link "DSLink6"

Hi, We are using DS 7.0 server Edition. Some times we are getting the entry in the log as given in subject. Jobs process 2000 rows ans stop processing after that. We checked the log of sequencer, it has called the jobs with Mode (row/warn limits) = 2000/50. But we didn't specify any limit while runn...
by urs_ravindra
Tue Jan 24, 2006 1:32 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: ds patch for win xp needed
Replies: 1
Views: 1497

ds patch for win xp needed

Hi, Can some body mail me the patch "ds patch for win xp". I'm not able to download it. Mail ID: urs_ravindra@yahoo.co.in We are not able to open a routine/job activity in a Sequencer job(in designer). This problem, i'm getting after my OS is upgrated to windows XP. And in all XP systems w...
by urs_ravindra
Mon Jan 23, 2006 11:01 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Error : "At Row 2000, DSLink Run Stopped"
Replies: 4
Views: 2041

No, many jobs in sequencer got stopped by giving this error. Nobody stopped any job and in all the jobs it is giving the same error.(Row 2000 link "link name" Run stopped.
by urs_ravindra
Mon Jan 23, 2006 10:45 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Error : "At Row 2000, DSLink Run Stopped"
Replies: 4
Views: 2041

Error : "At Row 2000, DSLink Run Stopped"

Hi Folks, We are using DS 7.0 server Edition. Many jobs are giving the following entry in log "At row 2000, link "Link_Name" Run stopped. It is not showing this as a warning or error. And job getting completed immediately(not proceeding further). Why this kind of abnormal termination ...
by urs_ravindra
Mon Jan 23, 2006 8:46 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Problem with Oracle stage(OraOCI9)
Replies: 12
Views: 5368

Re: Problem with Oracle stage(OraOCI9)

Hi,
I'm also facing same kind of problem (Windows XP work station). Can u plz send me the patch.
Mail ID: urs_ravindra@yahoo.co.in

Thanks in advance,
Ravindra
by urs_ravindra
Mon Jan 23, 2006 8:45 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Problem with Oracle stage(OraOCI9)
Replies: 12
Views: 5368

Re: Problem with Oracle stage(OraOCI9)

Hi,
I'm also facing same kind of problem (Windows XP work station). Can u plz send me the patch.

Thanks in advance,
Ravindra
by urs_ravindra
Mon Jan 23, 2006 8:30 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Not able to open Job/Routine activity in DS Designer
Replies: 2
Views: 1478

Not able to open Job/Routine activity in DS Designer

Hi Folks, We are using DS 7.0. I'm not able to open a routine/job activity in a Sequencer job(in designer). This problem, i'm getting after my OS is upgrated to windows XP. And in all XP systems we are not able to open job/Routine activities. Let me know what is the problem and how to over come this...