Search found 349 matches

by vinaymanchinila
Thu May 12, 2005 6:49 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: DS Upgrade Issue
Replies: 3
Views: 1574

If I dont solve the issue we have other projects which we have not run the jobs yet, and I can not rebuild them all over again !
Thanks,
by vinaymanchinila
Thu May 12, 2005 5:21 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: DS Upgrade Issue
Replies: 3
Views: 1574

Re: DS Upgrade Issue

Recently we upgraded from V6.0.1 to V7.5. In my project there are 70 jobs which have sucessfully run except for one job which is no different from the others! This job extracts data from SAP R/3 using ABAP Extract stage and writes to a flat file. When I run the job it gives: 1)Warning : Unknown: DS...
by vinaymanchinila
Wed May 11, 2005 2:38 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: DS Upgrade Issue
Replies: 3
Views: 1574

DS Upgrade Issue

Recently we upgraded from V6.0.1 to V7.5. In my project there are 70 jobs which have sucessfully run except for one job which is no different from the others! This job extracts data from SAP R/3 using ABAP Extract stage and writes to a flat file. When I run the job it gives: 1)Warning : Unknown: DSC...
by vinaymanchinila
Tue May 10, 2005 8:00 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Importing specific job design
Replies: 2
Views: 902

Thanks Craig, got it !
by vinaymanchinila
Tue May 10, 2005 6:27 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Importing specific job design
Replies: 2
Views: 902

Importing specific job design

Hi ,
Weekly we export all jobs to a .dsx file, now the issue is I need only one of the 125 jobs and how do I import that one job. If I have to import all the 125 jobs I am afraid it will overwrite all the other jobs which is scary!.
Thanks,
by vinaymanchinila
Thu May 05, 2005 7:22 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

Ravi,
Did you compile the job, if you drag output from 3 transformers to the input of link collector, when you compile it says"LINKCOLLECTOR does not support active stages" !
by vinaymanchinila
Thu May 05, 2005 5:26 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

Should it be In Process or Inter Process and how does it behave. How much should I select for buffer size.

But still I am thinking about the IPC stage not working and the reason for it.

Thanks,
by vinaymanchinila
Thu May 05, 2005 5:14 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

The whole point is of making the job more efficient, and not use the files. I can concatenate teh files int eh same job but why to go for it when I am able to connect the transformers throguh IPC stage to Link Collector.
The issue is the link collector doesnt look like it is working.
by vinaymanchinila
Wed May 04, 2005 12:21 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

I have used 3 IPC stages and then directly connected them to an Link collector and then to the target. The Issue is all the 3 transformers run fine and when the link comes to the IPC stage it just shows running. I stopped the job and increased the IPC connection time out to 999999. Still the job doe...
by vinaymanchinila
Wed May 04, 2005 10:52 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

The IPC doe not support more than one input dude!
by vinaymanchinila
Wed May 04, 2005 10:16 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

How would that solve the issue about connecting 3 transformers to a link collector. You mean use IPC in between the 3 ransformers and the link collector?
by vinaymanchinila
Wed May 04, 2005 10:12 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

When I use Link collector and drag the 3 output links from transformers , when I compile it says , likn collector does not support active stages.
by vinaymanchinila
Wed May 04, 2005 9:45 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

I did use append still when I use the files I get error saying required column missing when that particular column is nullable and not a key!.
So if I can avoid the files altogether and somehow link the 3 Xfms to the target.
Thanks,
by vinaymanchinila
Wed May 04, 2005 9:39 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: How to avoid using flat files & connect transformers out
Replies: 22
Views: 5988

How to avoid using flat files & connect transformers out

Hi,
I have 3 transformers generating data with same metadata. Instead of staging it into 3 flat files and merge them and load into Target, is there a way I can avoid the flat files and merge the output of the transformers . I did use the link collector but it doesnt take active inputs!

Thanks
by vinaymanchinila
Wed May 04, 2005 6:46 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Missing Column in Hash File
Replies: 14
Views: 3410

Hi Ray, I am using version 6.0.1 and in my job I have one source flat file, one ODBC look up, transformer and a target flat file. When I open the transformer stage, I have 3 link boxes. On the hash link when I right click or double click I donot find the "LinkProperty" option itslef!. Can ...