Search found 6 matches

by tbrosi
Wed Apr 03, 2013 1:16 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: DB/2 connector warning with unicode
Replies: 6
Views: 4842

Hi Michael,

thank you for your help.
I will check it.

Nevertheless it's curious that a known bug from version 8.5 still exists in 8.7.

Best regards
Thomas
by tbrosi
Wed Apr 03, 2013 12:59 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: DB/2 connector warning with unicode
Replies: 6
Views: 4842

Hi Michael,

I don't expect any unicode character in the actual case. But that can happen in the future.
The warning occurs when you select any varchar column, also with system tables like syscat.tables.

I tried using the UNICODE extended attribute but it didn't help.
by tbrosi
Tue Apr 02, 2013 10:32 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: DB/2 connector warning with unicode
Replies: 6
Views: 4842

Hi Michael,
I use DataStage 8.7.
The codepage of the database is UTF-8.

The warning only occurs in server jobs. In parallel jobs it works without any warning.
by tbrosi
Tue Apr 02, 2013 3:19 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: DB/2 connector warning with unicode
Replies: 6
Views: 4842

DB/2 connector warning with unicode

I'm using the DB/2 connector to read varchar columns from a database table. NLS is set to UTF8. I get a warning with the message id IIS-CONN-DAAPI-000395. The message says that the connector doesn't support data transmission in unicode format. Is there any possibility to get rid of this warning? I'v...
by tbrosi
Tue Mar 25, 2008 3:24 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Attachments in dssmtpmail.exe
Replies: 2
Views: 2466

Attachments in dssmtpmail.exe

We use dssmtpmail.exe to send an email to a list of users and want to
attach a file.
Does anybody know how this works?

At the moment we use ther parameter -message follwoed by the file name.
In this case the content of the file is sent as email body.

We want the file to be attached in the body.
by tbrosi
Tue Jun 19, 2007 11:09 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: execution of a job hangs after a few seconds
Replies: 2
Views: 1527

execution of a job hangs after a few seconds

On execution of a job hangs after a few seconds. The job design is as follows: ________________________________> T3______ SF_1 OCI1----> T1 ^ ^ __> HF_1------------>T2--------HF_3--------| | ^ ^ HF_4 OCI2_______________________| | | OCI3 ______> HF_2-------------------| There are three OCI stages. O...