Search found 166 matches

by thumsup9
Thu Nov 16, 2006 1:49 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: APT_CombineOperatorController:1:1:Content is not allowed in
Replies: 4
Views: 2097

Can you tell more about what you are doing here. Whats the data you are dealing with and whats your job design. A wild guess, are you dealing with xml files here.
by thumsup9
Thu Nov 16, 2006 1:40 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Attempting to Cleanup after Abort
Replies: 10
Views: 6968

What does log say when you reset the job and look for the log from previous run ?
by thumsup9
Wed Nov 08, 2006 2:10 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: SQL Server Bulk Load Error
Replies: 3
Views: 763

In our case its due to Permissions issue. Check with your DBA
by thumsup9
Thu Nov 02, 2006 3:53 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Read_delimited()- Required Column Missing
Replies: 23
Views: 8605

You can use 'Replace' in the Incomplete Column grid.
by thumsup9
Thu Nov 02, 2006 2:32 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Read_delimited()- Required Column Missing
Replies: 23
Views: 8605

If you want to get fewer columns that the 16 fields that exisit in the data then you will get this read delimited, may be you should check the box for Suppress Row Truncation Warnings..
by thumsup9
Thu Nov 02, 2006 10:39 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Load Flag Update in staging table
Replies: 2
Views: 1066

You can specify Reject Link in the transformer just before writing to your target.Reject links output rows that have not been written on any other output links from the Transformer stage. This way you can send these rows down the reject link to a flat file. In second job,using the flat file update t...
by thumsup9
Sun Oct 29, 2006 1:09 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Start Loop
Replies: 7
Views: 2009

Thanks Ray and Craig. I wanted to get back to you once I test it against our scenario and you know my answer, that fits perfectly.Thanks for all your inputs...

Thums !!
by thumsup9
Sat Oct 28, 2006 11:45 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Start Loop
Replies: 7
Views: 2009

Thx Craig and Kumar, I think i was confused and also confused you, I have main sequencer job sqDimensionLoad .It has 3 job activities, loadjob1,loadjob2,sqloadjob3 .( All these jobs take #BeginDate# retunred by a routine as input to run each day 10/28 ) sqloadjob3 is a sequencer by itself which has ...
by thumsup9
Fri Oct 27, 2006 9:07 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Start Loop
Replies: 7
Views: 2009

Start Loop

Hello All, I am currently running a job from a sequencer.The Sequencer has a Start Job Activity and End Loop. I have to run the same job for number of days say 20 or more. I am currently passing the a parameter in the start loop and the value is in format YYYYMMDD From -- #BeginDate# Step--- 1 To---...
by thumsup9
Thu Oct 19, 2006 11:35 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Job is Hanging
Replies: 4
Views: 1237

I remember Ray's quick fix advice to clear the Status file in your Director for this particular job and then running the job again.
by thumsup9
Thu Oct 19, 2006 11:29 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Decimal Format of " 000011." when viewing data
Replies: 5
Views: 1892

Ken,

I think its displaying correctly. The View Data shows both the precision and scale of the decimal data.
by thumsup9
Tue Oct 10, 2006 8:12 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: special character in Oracle schema owner name
Replies: 5
Views: 1910

ray.wurlod wrote:Welcome aboard. :D

Try surrounding the owner name in double quotes. For example "OPS$OWNER".TABLENAME

what happens when you SET QUOTED_IDENTIFER ON and then use the above example suggested by Ray
by thumsup9
Tue Oct 10, 2006 7:59 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: special character in Oracle schema owner name
Replies: 5
Views: 1910

ray.wurlod wrote:Welcome aboard. :D

Try surrounding the owner name in double quotes. For example "OPS$OWNER".TABLENAME

what happens when you SET QUOTED_IDENTIFER ON and then use the above example suggested by Ray
by thumsup9
Mon Oct 09, 2006 2:38 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Reason for mutex_unlock() Error ?
Replies: 11
Views: 5983

Do you have any other stages like IPC or Link Partioner in your job design. Once had a similar problem and removed the IPC and it performed OK. Another option I found in the forum is to check inter process under Enable row buffer option and increase the time out-say 60sec. HTH see I am working in p...
by thumsup9
Mon Oct 09, 2006 2:38 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Reason for mutex_unlock() Error ?
Replies: 11
Views: 5983

Do you have any other stages like IPC or Link Partioner in your job design. Once had a similar problem and removed the IPC and it performed OK. Another option I found in the forum is to check inter process under Enable row buffer option and increase the time out-say 60sec. HTH see I am working in p...