Thanks for the help,
The script will load data into a table which will be used by the next job, in that case after the script finishes running and moves on to the next job and if the table is still being loaded. How will it affect the next job?
Any thoughts on this
Thanks
Search found 224 matches
- Fri Jun 15, 2007 9:25 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: job sequence
- Replies: 16
- Views: 5274
- Thu Jun 14, 2007 11:01 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: job sequence
- Replies: 16
- Views: 5274
- Thu Jun 14, 2007 10:35 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: job sequence
- Replies: 16
- Views: 5274
- Thu Jun 14, 2007 10:25 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: job sequence
- Replies: 16
- Views: 5274
job sequence
I have 4 jobs and after each job completes i need to run a script , i need to know whether i can use before after sub routine in each job or in the job sequence i can use execute command stage.
Thanks all
Thanks all
- Tue Jun 05, 2007 2:51 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: moving records from seq file to netezza table
- Replies: 1
- Views: 780
moving records from seq file to netezza table
Hi,
Can someone help me out with the follwing error message
When checking operator: When validating export schema: At field "CHR_SRC_ID": Exporting nullable field without null handling properties
Thanks[/b]
Can someone help me out with the follwing error message
When checking operator: When validating export schema: At field "CHR_SRC_ID": Exporting nullable field without null handling properties
Thanks[/b]
- Tue Jun 05, 2007 9:03 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: julian to timestamp
- Replies: 6
- Views: 2310
- Mon Jun 04, 2007 3:38 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: julian to timestamp
- Replies: 6
- Views: 2310
julian to timestamp
how to convert 2454282 julian date to timestamp yyyy-mm-dd- 00:00:00
i am using basic transformer and
Oconv(Iconv(InLink.InputColumn, "DYJ"), "D-YMD[4,2,2]"):'00:00:00'.
what kind of julian dates are they 2454275,2454296?
any help is appreciated thanks.
i am using basic transformer and
Oconv(Iconv(InLink.InputColumn, "DYJ"), "D-YMD[4,2,2]"):'00:00:00'.
what kind of julian dates are they 2454275,2454296?
any help is appreciated thanks.
- Wed Jan 10, 2007 6:17 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: what is SIGINT
- Replies: 4
- Views: 2750
- Wed Jan 10, 2007 4:10 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Heap Allocation failure
- Replies: 2
- Views: 1758
Heap Allocation failure
hi, Can some one explain why do we get this kind of error message.
APT_CombinedOperatorController(),0: Fatal Error: Throwing exception: APT_BadAlloc: Heap allocation failed.[/b]
Thanks
APT_CombinedOperatorController(),0: Fatal Error: Throwing exception: APT_BadAlloc: Heap allocation failed.[/b]
Thanks
- Wed Jan 10, 2007 4:03 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: what is SIGINT
- Replies: 4
- Views: 2750
what is SIGINT
Hi Guys,
What is this error?
main_program: ORCHESTRATE step execution terminating due to SIGINT
Parallel job was aborted
What is this error?
main_program: ORCHESTRATE step execution terminating due to SIGINT
Parallel job was aborted
- Tue Nov 22, 2005 10:08 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Job Sequences
- Replies: 4
- Views: 2771
- Tue Nov 22, 2005 9:52 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Job Sequences
- Replies: 4
- Views: 2771
- Tue Nov 22, 2005 9:44 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Job Sequences
- Replies: 4
- Views: 2771
Job Sequences
I have 9 Job Sequences and I want to run all the Job Sequences in one Sequenece. Is that possible?
Appreciate any post in this regard.
Thanks
Appreciate any post in this regard.
Thanks
- Fri Oct 21, 2005 9:21 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Phantom Aborting with @ABORT.CODE = 1
- Replies: 3
- Views: 2972
Phantom Aborting with @ABORT.CODE = 1
DataStage Job 378 Phantom 8288
DataStage Phantom Aborting with @ABORT.CODE = 1
DataStage Phantom Aborting with @ABORT.CODE = 1