Hi All
Kindly request your help in this regard.
How is an upgrade carried out in a Grid environment from IIS v8.5 to IIS 9.1
Thanks
George
Search found 11 matches
- Tue Jan 07, 2014 1:05 pm
- Forum: General
- Topic: DataStage Upgrade
- Replies: 5
- Views: 4061
- Fri Dec 27, 2013 1:51 pm
- Forum: General
- Topic: DataStage Upgrade
- Replies: 5
- Views: 4061
- Fri Dec 27, 2013 1:09 pm
- Forum: General
- Topic: DataStage Upgrade
- Replies: 5
- Views: 4061
DataStage Upgrade
Hi All, We are currently in the process of upgrading from DataStage v8.5 to v9.1 Linux is the Platform that is used currently and will be used for the future version as well. I have never worked in an upgrade project before and would like to understand the steps that should be performed for upgradin...
- Tue Dec 17, 2013 9:02 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Varchar field length
- Replies: 4
- Views: 4049
Hi All, Thanks for your replies. As I mentioned I prefer defining the length of the varchar field but since its a response from some other system I dont have control over that and further they too told it is dynamic and change. When we dont define the length for a varchar field what is the length th...
- Tue Dec 17, 2013 4:01 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Varchar field length
- Replies: 4
- Views: 4049
Varchar field length
Hi All, I'm trying to read a xml message into a varchar field. The length of the xml message could vary and I'm reading it into a single nvarchar field. As of now I have not defined any length for the nvarchar field as the length of the message could vary. I have 2 approaches in mind: 1. Define a ve...
- Mon Nov 04, 2013 4:14 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Grid compute node
- Replies: 7
- Views: 6895
- Mon Nov 04, 2013 2:48 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Grid compute node
- Replies: 7
- Views: 6895
Grid compute node
Hi All, Can you please let me know why we would pass 2 values to APT_Grid_computenodes From what I read about the Apt variable I was thinking it should have a single value passed to it. But in the current environment for a new customer I see values passed like the below: Apt_grid_computenodes=2,2 or...
- Mon Nov 04, 2013 12:22 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DS to Cassandra
- Replies: 2
- Views: 2406
DS to Cassandra
Hi All, Please let me know if it is possible to connect to Cassandra server using DataStage Java Client/Java Transformer Stage. There is no driver for Cassandra available in the DataStage server. I would like to know if there is a way to connect to Cassandra directly using pure Java code without any...
- Mon Nov 04, 2013 12:09 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DB2 Connector
- Replies: 6
- Views: 3568
- Fri Nov 01, 2013 3:51 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DB2 Connector
- Replies: 6
- Views: 3568
Hi Ray, Thank you for your reply. Hi MT, My job flow is below: Sequential File --> DB2 Connector I saw the partitioning icon in the link which flows from the Sequential file to DB2 Connector and it shows the symbol wherein data is converging into the DB2 Connector. I opened the different tabs in the...
- Thu Oct 31, 2013 9:51 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DB2 Connector
- Replies: 6
- Views: 3568
DB2 Connector
Hi All, I have a Parallel Job which has an input Sequential Stage which feeds data to a DB2 Connector Stage which updates a table. In the DB2 Connector Stage in the Partitioning tab the Collector Type is specified as 'Auto'. Please let me know if the DB2 Update would run in parallel or in sequential...