Search found 33 matches

by Salegueule
Wed Oct 17, 2012 11:21 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Paraccel or Kognitio Compatibility with DS
Replies: 1
Views: 1147

Paraccel or Kognitio Compatibility with DS

Does anybody know if the newer versions of Datastage have plugins for Paraccel and Kognitio??

I know that they have it for Netezza but I'm not finding much on these two.

We are currently under 7.5.1 but will upgrade our DB2 to one of these plateforms.

Thank you!
by Salegueule
Wed Apr 18, 2012 2:26 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: ODBC Driver only shows public role tables
Replies: 0
Views: 1062

ODBC Driver only shows public role tables

Hi, We are using the ODBC (5.3) Plug In to access an Informix database using Wire Protocol. When importing table structure with Manager it does not shows the entire list of the tables. We see all the Informix sys tables and some other that are all affected to Public role. Strangely using a Windows O...
by Salegueule
Wed Nov 04, 2009 12:39 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Maximum Parameter Length
Replies: 2
Views: 2264

Maximum Parameter Length

Hi,

I have done some research but did not found the answer.

What is the maximum char length that can be use in a string parameter?
by Salegueule
Thu Sep 10, 2009 9:48 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: How do we set the DB2DIR variable?
Replies: 2
Views: 3311

How do we set the DB2DIR variable?

Having connectivity problem with DB2 after migrating to V9. In Director I see that we are still poinitng to DB2 V8. The DB2DIR variable do not seems to be iclude in the DS Administrator Environment panels. Curently we have DB2DIR=/usr/opt/db2_08_01 Where do we set this variable? Besides the path ,do...
by Salegueule
Thu Jan 22, 2009 4:20 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Setting microsecond portion of Timestamp???
Replies: 4
Views: 1775

ray.wurlod wrote:What is the format picture you are using for the timestamp? Does it include the fractional seconds part? ...
Hi,

I am using the following:

CONSENT_END_TIMEST: timestamp[microseconds] {text, timestamp_format="%yyyy-%mm-%dd-%hh.%nn.%ss.6"}

Thanks!
by Salegueule
Thu Jan 22, 2009 4:17 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Setting microsecond portion of Timestamp???
Replies: 4
Views: 1775

kandyshandy wrote:Did you try concatenating timestamp part with hardcoded '.999999' and loading them to target field?
Hi,

Yes I have tried that and not working for me.
by Salegueule
Thu Jan 22, 2009 3:24 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Setting microsecond portion of Timestamp???
Replies: 4
Views: 1775

Setting microsecond portion of Timestamp???

Hi, I am working on converting some ETL programs from COBOL MVS to Unix DataStage PX. On some condition, one of the COBOL program is setting a timestamp column to '9999-12-31 23:59:59.999999'. Although DataStage does not seems to kick or issue warning of any sorts, I am getting '9999-12-31 23:59:59....
by Salegueule
Thu Jul 24, 2008 4:29 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Problem reading DB2 character for bit data column
Replies: 0
Views: 1088

Problem reading DB2 character for bit data column

Hi, I have to retreive the content of two DB2 columns that are produced by the IBM DPROP utility. These columns are declared as: CHARACTER(10) for bit data with content looking like this from Quest: x'0000208E216190000000'. What I have to do is basic. In the case that the source record does not sati...
by Salegueule
Fri Jun 15, 2007 9:52 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Does only SORT stages generates Tsort merger abort erros?
Replies: 2
Views: 1595

Does only SORT stages generates Tsort merger abort erros?

Hi, I am getting the following in my job output: cs}}},2: Fatal Error: Tsort merger aborting: Scratch space full [sort/merger.C:870] I know that increasing the scratch disk will resolved the problem but what I would like to know after reading on similar topics in this forum is; is it only the SORT s...
by Salegueule
Tue Feb 13, 2007 5:35 pm
Forum: General
Topic: XML Input Stage and XSL
Replies: 1
Views: 1441

XML Input Stage and XSL

Does anybody has any success in using a stylesheet with the XML Input Stage? I am trying to get the stage to use a simple stylesheet but get full of warnings such as: XSLT Processor: Unknown element on the output. Element Name = "CustomerName" When I am removing the stylesheet reference my...
by Salegueule
Mon Oct 23, 2006 4:08 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Compiling error on Transform stage using TRIM with L option
Replies: 2
Views: 1382

Compiling error on Transform stage using TRIM with L option

Hi, Having an error compiling a transform stage susing the following: CompactWhiteSpace(Trim(TPRTNLOC_01.STREET_NUMBER,"0","L"):" ": TPRTNLOC_01.STREET_NUMBER_SUFF:" ": TPRTNLOC_01.SUITE_NUMBER:" ": TPRTNLOC_01.STREET_NAME:" ": TPRTNLOC_01....
by Salegueule
Thu Jan 05, 2006 9:36 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: DS Job Warnings Removal
Replies: 2
Views: 1391

DS Job Warnings Removal

Hi, Is there a way that we can have Data Stage to avoid generating Warning messages? I am calling a Data Stage job from a shell script in a loop sequence in order to validate the format of submitted files from the client. When a file is not compliant with the format we expect, my script takes care o...
by Salegueule
Tue Oct 11, 2005 9:14 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: PX Join Stage - Full Outer
Replies: 3
Views: 1424

PX Join Stage - Full Outer

Hi, I need to merge 2 files together that have the same composite key structure. I am using a Join stage with the Full Outer join option. File 1: Column Key (y/n) --------- ----------- Report_date y Level_1 y Level_2 y Level_3 y WorkVolume n File 2: Column Key (y/n) --------- ----------- Report_date...
by Salegueule
Fri Aug 19, 2005 5:23 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: PX Job not terminating
Replies: 3
Views: 1867

PX Job not terminating

Looks like a job started yesterday at 7:55 Pm yesterday do not terminate. I am seeing that it have been running all night now for almost 11 hrs. I have first try to stop it from Director. It does not do anything, it is still running. Although we seems to have kill all related process yesterday night...
by Salegueule
Mon Aug 08, 2005 8:14 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: DFloatToDecimal
Replies: 4
Views: 3523

ray.wurlod wrote:You can rely on implicit casts in a BASIC Transformer stage.
Thank you Ray.

Should I been worried about any performance hit using a Basic Transform instead of the PX native Transform?

What should be the guidelines in using one or the other?

Is it something documented in the Onine manuals?