Search found 3 matches

by ramkumar.krishnan
Wed Feb 23, 2011 4:40 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: conductor node
Replies: 1
Views: 1331

Re: conductor node

hi im a datastage beginner. could anyone breifly explian about conductor node and its real time usage. It is better to study the run-time architecture of DataStage Parallel framework Conductor Node : It is a main process to i) Start up jobs ii) Resource assignments iii) Responsible to create Sectio...
by ramkumar.krishnan
Wed Feb 02, 2011 2:37 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: FATAL Error in transformer
Replies: 8
Views: 5114

split teh job. It Seems like System resources reached more than allocated resources.Below are some of the causes of job termination. # Operating System limit reached maximum of it's capacity. ( No of processes allocated for individual user) # Scratch disk space is overfilled while the job is runnin...
by ramkumar.krishnan
Thu Jan 06, 2011 1:21 am
Forum: General
Topic: Datastage upgrade from 7.5 to 8.5
Replies: 10
Views: 12811

Re: Datastage upgrade from 7.5 to 8.5

1. All the jobs & routines compatible with new version except some of oracle OCI stages. (Oracle OCI 8 stage is not supported in new version,need to replace with OCI 9 stage)

2. If it is server jobs, make sure you have populated required hashed files and check the permission's for routines.