Search found 3 matches
- Wed Feb 23, 2011 4:40 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: conductor node
- Replies: 1
- Views: 1331
Re: conductor node
hi im a datastage beginner. could anyone breifly explian about conductor node and its real time usage. It is better to study the run-time architecture of DataStage Parallel framework Conductor Node : It is a main process to i) Start up jobs ii) Resource assignments iii) Responsible to create Sectio...
- Wed Feb 02, 2011 2:37 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: FATAL Error in transformer
- Replies: 8
- Views: 5114
split teh job. It Seems like System resources reached more than allocated resources.Below are some of the causes of job termination. # Operating System limit reached maximum of it's capacity. ( No of processes allocated for individual user) # Scratch disk space is overfilled while the job is runnin...
- Thu Jan 06, 2011 1:21 am
- Forum: General
- Topic: Datastage upgrade from 7.5 to 8.5
- Replies: 10
- Views: 12811
Re: Datastage upgrade from 7.5 to 8.5
1. All the jobs & routines compatible with new version except some of oracle OCI stages. (Oracle OCI 8 stage is not supported in new version,need to replace with OCI 9 stage)
2. If it is server jobs, make sure you have populated required hashed files and check the permission's for routines.
2. If it is server jobs, make sure you have populated required hashed files and check the permission's for routines.