Search found 39 matches

by kiran0435
Wed Jun 22, 2011 12:52 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Environmental variable clarification
Replies: 3
Views: 2278

Environmental variable clarification

My development server contains a user defined environmental variable CC_MSG_LEVEL which was by default set to 1. It caused me problem in some loading data so I set it to 0 and jobs are running fine. But my production server doesn't contain this variable. How to add this variable in that environment....
by kiran0435
Mon Jun 20, 2011 1:58 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Discrepency from 8.1 to 8.5v
Replies: 11
Views: 8665

no... just my job performs join(where i get some id and timestamp based on keys)... followed by transformer where i separate records based on some value.... in that transformer... in 8.1v records are getting dropped for null timestamps... but in 8.5v records are moving to final dataset even the fiel...
by kiran0435
Sun Jun 19, 2011 11:24 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Discrepency from 8.1 to 8.5v
Replies: 11
Views: 8665

No operation is performed on this data. Just move.
by kiran0435
Sun Jun 19, 2011 10:57 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Discrepency from 8.1 to 8.5v
Replies: 11
Views: 8665

i have set the LEGACY NULL PROCESSING option as well as $APT_TRANSFORM_COMPILE_NULL_HANDLING, but the records are not dropping which is my requirement.
by kiran0435
Sun Jun 19, 2011 10:53 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Discrepency from 8.1 to 8.5v
Replies: 11
Views: 8665

yes,

transformer drops it. No constraint.


I have set mentioned environmental variable to 'True' and ran the jobs. But i am getting the same result.
by kiran0435
Sun Jun 19, 2011 10:31 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Discrepency from 8.1 to 8.5v
Replies: 11
Views: 8665

the legacy null processing option is checked by default. Is there anything else to look upon.
by kiran0435
Sun Jun 19, 2011 9:42 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Discrepency from 8.1 to 8.5v
Replies: 11
Views: 8665

Discrepency from 8.1 to 8.5v

Hi, I performed inner join and inner join is expected to get match for all business keys from source. The join stage is followed by a transformer for some additional operations. If the invalid source records comes then matching ID will not be found in the join stage and record gets dropped in transf...
by kiran0435
Tue Jun 14, 2011 11:39 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Bulk Load Option for DB2 Connector Stage
Replies: 3
Views: 9288

Issue Resolved. The job took time due to CC_MSG_LEVEL being enabled at project level. This generated huge logs in director and job was crashing for huge volume. Disbaled the env variable CC_MSG_LEVEL and Bulk load went on fly. Points to be noted for Bulk load: 1. Table should be partitioned 2. Non r...
by kiran0435
Wed Jun 08, 2011 12:45 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Bulk Load Option for DB2 Connector Stage
Replies: 3
Views: 9288

Bulk Load Option for DB2 Connector Stage

Hi we are using DS 8.1 We able to execute bulk load using DB2 Connector only for less volume of records. It breaks when volume is huge. Bulk load also takes more time compared to Normal insert. I have set Non recoverable load to YES. Normal insert: 189K records: 3:44 mins Bulk load: 80K records: 1:1...