Search found 19 matches
- Mon May 06, 2013 10:03 am
- Forum: General
- Topic: Client install both 8.7 and 9.2
- Replies: 5
- Views: 3903
I asked my Admins if I can change the ports, both of them informed me to used same ports. Tried option of installing 8.7 and shutdown and tried to install 9.1 (all client tiers), same error. Tried option of installing 8.7 and shutdown and tried to install 9.1 Datastage only, Install successful. Afte...
- Sun May 05, 2013 5:36 pm
- Forum: General
- Topic: Client install both 8.7 and 9.2
- Replies: 5
- Views: 3903
- Sun May 05, 2013 12:37 pm
- Forum: General
- Topic: Client install both 8.7 and 9.2
- Replies: 5
- Views: 3903
Client install both 8.7 and 9.2
Hi I have IIS 8.7 on my system and I tried to install IIS 9.2 (will be working on multiple projects) . While installing 9.2 I am getting "Port 19443 is not available" error. When taking to both 8.7 and 9.2 admins, they confirmed to use "19443" port. How to install 9.2 with the sa...
- Mon Jul 09, 2012 1:43 pm
- Forum: General
- Topic: Job running fine but in sequence aborts
- Replies: 6
- Views: 2832
Re: Job running fine but in sequence aborts
Job parameters.
- Mon Jul 09, 2012 1:40 pm
- Forum: General
- Topic: Job running fine but in sequence aborts
- Replies: 6
- Views: 2832
Re: Job running fine but in sequence aborts
compare variables used by job when run from sequence and run individually and see if there is any difference.
- Mon Jul 09, 2012 1:00 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: APT_ParallelSortMergeOperator : Unbalanced input
- Replies: 12
- Views: 6389
Re: APT_ParallelSortMergeOperator : Unbalanced input
if you have good memory use lookup stage or re-partisan depending on record count Or add MsgHandlers
- Sun Apr 15, 2012 7:28 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ODBC DSN in odbc.ini
- Replies: 3
- Views: 1886
- Fri Apr 13, 2012 2:58 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ODBC DSN in odbc.ini
- Replies: 3
- Views: 1886
ODBC DSN in odbc.ini
While creating a new SQL Server DSN in .odbc.ini, is it possible to add the below parameter to it? This is an effort to see if the ODBC SQL Server timeout never happens if this is possible. The datadirect version that is considered in this case is Data Direct 6.0.
LoginTimeout=0
Thanks!
LoginTimeout=0
Thanks!
- Wed Apr 11, 2012 9:18 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ODBC SQL Server Driver Timeout expired error
- Replies: 4
- Views: 3780
Re: ODBC SQL Server Driver Timeout expired error
So far we also resorted to restarting the jobs.
- Wed Apr 11, 2012 9:15 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ODBC SQL Server Driver Timeout expired error
- Replies: 4
- Views: 3780
- Tue Apr 03, 2012 9:14 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ODBC SQL Server Driver Timeout expired error
- Replies: 4
- Views: 3780
ODBC SQL Server Driver Timeout expired error
Hi, I am using datastage version 7.5.2. There are several jobs in the project that connect to SQL Server database using ODBC stage. Randomly the jobs are failing with the below error. Some of the times the jobs are running absolutely fine but other times they fail with time out error. "APT_Comb...
- Fri Feb 24, 2012 2:33 pm
- Forum:
- Topic: Training Class - Metadata Workbench
- Replies: 2
- Views: 1551
Re: Training Class - Metadata Workbench
Hi Ray, Sorry I could not attend this training. Are there any recorded videos/documents for this session? if yes, how can we access them.
- Wed Dec 21, 2011 3:53 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: XML output formatting
- Replies: 1
- Views: 1729
Re: XML output formatting
since it is in one parentinfo, you need to remove duplicate after reading complete file.
- Wed Dec 21, 2011 1:57 pm
- Forum: General
- Topic: No Engine credentials were found on the Services Tier
- Replies: 15
- Views: 11232
Re: No Engine credentials were found on the Services Tier
you can select all 50 user and map their crediantials at once, it might be hard initially but will get used to it :D .
- Wed Dec 21, 2011 9:16 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: MQ Client Setup
- Replies: 2
- Views: 2327
Re: MQ Client Setup
IBM has migrator tool which migrates plugins to connectors, try that and it might work.