Search found 195 matches
- Mon Jul 12, 2010 9:06 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: TD Ent stage returns: Insufficient blocks for partition 2.
- Replies: 1
- Views: 1616
TD Ent stage returns: Insufficient blocks for partition 2.
Have seen several posts regarding this error but it seems most of them were realted to a lookup. In my case the situation is a TD Enterprise stage feeding a Transformer. The following error occurs occassionally: TD_GET_EmailSuppresionInfo,2: Insufficient blocks for partition 2. Reading suppressed. I...
- Tue Jun 22, 2010 11:01 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Accessing files from remote host
- Replies: 7
- Views: 3234
- Tue Jun 08, 2010 4:49 pm
- Forum: General
- Topic: apt_terasync_daemon_prog
- Replies: 2
- Views: 1078
- Tue Jun 08, 2010 11:06 am
- Forum: General
- Topic: apt_terasync_daemon_prog
- Replies: 2
- Views: 1078
apt_terasync_daemon_prog
I found environment variable apt_terasync_daemon_prog set to an IP address in DS administrator; however, I don't find it in either the Parallel Adevanced Developer Guide nor the Teradata Connectivity Guide.
Any idea what it is? And/or what is going to happen when I remove it?
Any idea what it is? And/or what is going to happen when I remove it?
- Wed Apr 28, 2010 1:01 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequencer job status when command activity fails
- Replies: 10
- Views: 8495
- Wed Apr 28, 2010 12:40 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequencer job status when command activity fails
- Replies: 10
- Views: 8495
- Wed Apr 28, 2010 12:21 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequencer job status when command activity fails
- Replies: 10
- Views: 8495
actually to be a bit more precise, the command is a sudo command to execute a script. In director I see the following: RMKD400W..JobControl (@TRANSFER2MAINFRAME): Command sudo did not finish OK, reply = '1' RMKD400W..JobControl (@Coordinator): Summary of sequence run 12:13:02: Sequence started (chec...
- Wed Apr 28, 2010 12:07 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequencer job status when command activity fails
- Replies: 10
- Views: 8495
- Wed Apr 28, 2010 9:29 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequencer job status when command activity fails
- Replies: 10
- Views: 8495
Sequencer job status when command activity fails
dsjob is returning 0 even when command activity fails. I am working on a script that calls dsjob to submit a DS sequencer. The Sequencer contains job activities and command activities. The script is looking for the return code coming from the dsjob command expecting a non-zero value if anything fail...
- Mon Apr 05, 2010 1:54 pm
- Forum: IBM QualityStage
- Topic: How to hande addresses with Puerto Rican token
- Replies: 10
- Views: 7869
- Fri Apr 02, 2010 3:20 pm
- Forum: IBM QualityStage
- Topic: How to hande addresses with Puerto Rican token
- Replies: 10
- Views: 7869
- Fri Apr 02, 2010 2:16 pm
- Forum: IBM QualityStage
- Topic: How to hande addresses with Puerto Rican token
- Replies: 10
- Views: 7869
I could not find a way to enter ? as the classification so I chose + Unknown word for both Casa and Villa. Testing though still leaves me confused: 234 CASA BONITA CIRCLE results in: UnhandledPattern = ^++T UnhandledData = 234 CASA BONITA CIRCLE InputPattern = ^++T 234 CAS BONITA CIRCLE results in: ...
- Thu Apr 01, 2010 3:35 pm
- Forum: IBM QualityStage
- Topic: How to hande addresses with Puerto Rican token
- Replies: 10
- Views: 7869
- Thu Apr 01, 2010 2:53 pm
- Forum: IBM QualityStage
- Topic: How to hande addresses with Puerto Rican token
- Replies: 10
- Views: 7869
How to hande addresses with Puerto Rican token
using the USADDR ruleset I am find addresses that contain a Puerto Rican (P) token somewhat problematic. for example: 122 Villa Oaks street has a token pattern of ^P+T sends the entire address to UnhandledData with an Unhandled Pattern of ^P++ I realize I could fix this by adding token patterns of ^...
- Thu Mar 04, 2010 6:23 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sort: DataStage vs. Unix
- Replies: 2
- Views: 3788
Sort: DataStage vs. Unix
I've read through many posts here regarding sorts but, as often happens, I'm left with as many new questions as answers. What are the primary considerations when deciding between using the DataStage vs. Unix Sort? Is DataStage preferred for sorting datasets, and Unix for Sequential files? And, other...