Hi,
Iam using aggregator stage for calculating amounts. In the output iam getting small difference. Below is the example
Input Output
12.34 12.32
99.99 99.97
78.23 78.21
Should i need to change any options so that i can get acurate result...
Search found 9 matches
- Fri Jul 23, 2010 2:17 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Aggregator Stage error
- Replies: 2
- Views: 1553
- Fri Jul 23, 2010 1:01 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Copy Stage
- Replies: 3
- Views: 3383
Re: Copy Stage
Hi I have a doubt regarding the copy stage is it required to set TRUE or FALSE in copy stage properties. If so can you please mention the reason for doing so?? "Where you are using a Copy stage with a single input and a single output, you should ensure that you set the Force property in the st...
- Fri Jul 23, 2010 11:42 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Copy Stage
- Replies: 3
- Views: 3383
Copy Stage
Hi I have a doubt regarding the copy stage is it required to set TRUE or FALSE in copy stage properties. If so can you please mention the reason for doing so??
- Mon Jul 12, 2010 11:51 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: how to specify Sparse Lookup
- Replies: 2
- Views: 2755
how to specify Sparse Lookup
Iam new to datastage and i came to know about sparse lookup. I tried to see that option in the Look Up Stage but i coudnt find it. Can you please specify me in brief how to specify and where in the lookup stage.
- Tue Jun 01, 2010 6:54 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: CFF Stage problme in Parallel job
- Replies: 7
- Views: 5605
CFF Import Error
Thanks for the information Kryt0n. My problem was solved. But this is not due to the Packed decimal fields. Below is the problem and the solution I implemented to make it work. There are the 4 types of fields listed in the copybook and below different phases of changes I found for these fields. Cop...
- Mon May 31, 2010 3:14 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: CFF stage reading Mainframe Dataset that has S9(S) Comp -3
- Replies: 13
- Views: 9564
Extracting Mainframe data with Comp3 &loading into Seq F
What is your actual error - the heap size message is a warning, not a fatal error and might have nothing at all to do with your real problem. ... Iam using Datastage 8.1 and iam unable to read the cobol data and write it into the sequential files. Iam not flattening the arrays ,Removing the group c...
- Fri May 28, 2010 11:28 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: CFF stage reading Mainframe Dataset that has S9(S) Comp -3
- Replies: 13
- Views: 9564
CFF stage reading Mainframe Dataset that has S9(5) Comp -3
Was "S9(5) COMP-3" a typographical error? Can you do a "view data" from your DataStage designer (I am assuming the HEAP error is a runtime one)? Also, could you cut-and-paste the complete actual error message? Sorry it was S9(5) Comp -3 data i was reading from Mainframe to Seque...
- Thu May 27, 2010 4:57 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: CFF stage reading Mainframe Dataset that has S9(S) Comp -3
- Replies: 13
- Views: 9564
Reading Mainframe Data throough CFF Stage
Welcome aboard. If you import the "table definition" from a relevant COBOL copybook, then all of the required metadata will be there for you. As a general rule field sizes are fixed in mainframe data, so there is no field delimiter and no need for quotes. The record delimiter will depend ...
- Thu May 27, 2010 9:33 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: CFF stage reading Mainframe Dataset that has S9(S) Comp -3
- Replies: 13
- Views: 9564
CFF stage reading Mainframe Dataset that has S9(S) Comp -3
Hi All, Iam having trouble reading the data from Mainframe Dataset using the complex flat file. It has dataset S9(s) comp-3.( Datastage version 8.1.1) can you please help me with this issue. I had seen all the posts and followed everything but still it dint work for me.. Can you please speficiy 1.wh...