Search found 614 matches
- Wed Oct 06, 2010 2:58 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: double quotes in the field values.
- Replies: 1
- Views: 1613
double quotes in the field values.
Hi All , I have file csv with double quotes and the data is as below , Though the format in datastage job is given as Delimiter=, quotes=double For two of the fields Misc Description and Security description ,when the data is viewed thru datastage browser the values still contain double quotes. Beca...
- Thu Sep 30, 2010 11:27 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequential stage file view error.
- Replies: 2
- Views: 1597
Sequential stage file view error.
Hi All , When I am trying to view empty file I am getting following error messages , I would expect the message to be file is emptyor just see the header column names. Any inputs on why I am getting below messages. It runs 1 process on 1 node. ##I TOIX 000163 12:11:25(000) <Copy_of_src_Corporate_Act...
- Tue Sep 28, 2010 1:50 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequential stage quote=double, how does that work?
- Replies: 5
- Views: 2077
- Tue Sep 28, 2010 1:19 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: offset warning in the sequential stage
- Replies: 4
- Views: 4151
- Tue Sep 28, 2010 1:15 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequential stage quote=double, how does that work?
- Replies: 5
- Views: 2077
Sequential stage quote=double, how does that work?
Hi All , In Sequential stage , in the format tab if the values are set as delimiter=comma and quote= double , ie; if I have files coming as csv without quotes and a csv with quotes , can I have the properties set as above.. I tried reading for csv without quotes and csv with quotes and it read the f...
- Tue Sep 28, 2010 11:03 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: In the Sort output I need get record with minimum time diff
- Replies: 2
- Views: 989
In the Sort output I need get record with minimum time diff
Hi All, I 've the data in following way field 5 is time difference in seconds. I've sorted and hash partioned the output with fields 2,3,4,5 and would be as below x1, a,b,c, 10 x2, a,b,c,10 x3, a,b,c,30 x4, a,b,c,40 x5, a1,b1,c1,5 x6,a1,b1,c1,10 x6,a1,b1,c1,15 From the above output I need get the fo...
- Fri Sep 24, 2010 1:20 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sort stage warnings
- Replies: 3
- Views: 2253
- Fri Sep 24, 2010 11:08 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Warning in Sort and Rem Duplicates stages.
- Replies: 1
- Views: 1873
Warning in Sort and Rem Duplicates stages.
Hi All, I am getting following warnings in Sort and Remove duplicates stages. For sort stage below warning sort_time_diff: Data claims to already be sorted on the specified keys the 'sorted' option can be used to confirm this. Data will be resorted as necessary. Performance may improve if this sort ...
- Fri Sep 24, 2010 11:00 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sort stage warnings
- Replies: 3
- Views: 2253
Sort stage warnings
Hi All, I am getting following warnings in sort stage, sort_time_diff: Data claims to already be sorted on the specified keys the 'sorted' option can be used to confirm this. Data will be resorted as necessary. Performance may improve if this sort is removed from the flow Any thoughts why I am getti...
- Tue Sep 21, 2010 2:02 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: difference in timestamps..
- Replies: 4
- Views: 2438
Thank you all for your responses. But my input times are from file (ie; is varchar) and as below Time 1 is 8/4/2010 12:40 Time 2 is 8/4/2010 12:41 I see many functions are available but could someone please suggest me with some data/time functions with exact format as help is not very clear for me. ...
- Mon Sep 20, 2010 10:35 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: How to lookup for the closest value?
- Replies: 6
- Views: 1833
Re: How to lookup for the closest value?
Hi All, How to lookup for the closest value for time as below , Settle Dates are same AND Share Quantity are same AND Mainframe Time Stamp are same or the closest AND The first 3 digits of the SS Asset ID for both the records are same. Mainframe Time Stamp format is 8/20/2010 16:04 source and targe...
- Fri Sep 17, 2010 12:59 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: How to lookup for the closest value?
- Replies: 6
- Views: 1833
- Fri Sep 17, 2010 9:03 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: How to lookup for the closest value?
- Replies: 6
- Views: 1833
How to lookup for the closest value?
Hi All, How to lookup for the closest value for time as below , Settle Dates are same AND Share Quantity are same AND Mainframe Time Stamp are same or the closest AND The first 3 digits of the SS Asset ID for both the records are same. Mainframe Time Stamp format is 8/20/2010 16:04 source and target...
- Wed Sep 15, 2010 11:14 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: log in the director
- Replies: 2
- Views: 1225
log in the director
Hi All , For a job in the director after I run , I am not able to see all the log from the beginning ie; setting up of environment variables ...all those, even if i scroll up it does not show from the start point , and this job has lot stages in it and it is bit big one .. is this the reason that I ...
- Wed Sep 15, 2010 8:34 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: offset warning in the sequential stage
- Replies: 4
- Views: 4151
offset warning in the sequential stage
Hi All ,
I am getting the following warning for a csv file
seq_src_PORTFOLIO_LKP,0: Delimiter for field "IP_PORTFOLIO" not found; input: {0d}, at offset: 0
seq_src_PORTFOLIO_LKP,0: Import warning at record 27.
any inputs greatly appreciated , thanks in advance.
I am getting the following warning for a csv file
seq_src_PORTFOLIO_LKP,0: Delimiter for field "IP_PORTFOLIO" not found; input: {0d}, at offset: 0
seq_src_PORTFOLIO_LKP,0: Import warning at record 27.
any inputs greatly appreciated , thanks in advance.