Thanks Ray..
Update timestamp should be in min and max times range..
Search found 614 matches
- Mon Nov 18, 2013 1:27 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Range look up for timestamp fields.
- Replies: 3
- Views: 3218
- Mon Nov 18, 2013 12:16 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Range look up for timestamp fields.
- Replies: 3
- Views: 3218
Re: Range look up for timestamp fields.
Below is peek o/p Peek_422,0: MINIMUM_TIMESTAMP:2004-01-18 15:12:37 MAXIMUM_TIMESTAMP:2004-01-21 11:58:13 UPDATE_TIMESTAMP:2013-07-02 01:51:08.028874 Peek_422,1: MINIMUM_TIMESTAMP:2004-01-18 15:12:37 MAXIMUM_TIMESTAMP:2004-01-21 11:58:13 UPDATE_TIMESTAMP:2013-07-02 01:51:08.028874 Peek_422,0: MINIMU...
- Mon Nov 18, 2013 10:44 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Range look up for timestamp fields.
- Replies: 3
- Views: 3218
Range look up for timestamp fields.
Hi all, I am trying to range look up..on the reference link.. My input source column is updatetimestamp field looking up between mintimestamp and maxtimstamp fields in the reference getting the datadate value.. Range expression is as below.. the job is running but not correctly the datadate value is...
- Tue Nov 12, 2013 3:48 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: RmDp_3: When checking operator: User inserted sort "Srt
- Replies: 6
- Views: 5442
- Tue Nov 12, 2013 2:19 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: RmDp_3: When checking operator: User inserted sort "Srt
- Replies: 6
- Views: 5442
- Tue Nov 12, 2013 12:25 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: RmDp_3: When checking operator: User inserted sort "Srt
- Replies: 6
- Views: 5442
- Tue Nov 12, 2013 9:59 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: RmDp_3: When checking operator: User inserted sort "Srt
- Replies: 6
- Views: 5442
RmDp_3: When checking operator: User inserted sort "Srt
Getting following warning and couldn't fix it.. any help appreciated.. RmDp_3: When checking operator: User inserted sort "Srt_3" does not fulfill the sort requirements of the downstream operator "RmDp_3" Used same partition method and keys in rem dup stage. In sort stage with sa...
- Wed Oct 30, 2013 12:30 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Netezza Warning Process meta data not available in database
- Replies: 0
- Views: 2024
Netezza Warning Process meta data not available in database
Hi All, INSERT_NSTAR_LOGGING_CATEGORY_CROSS_REFERENCE: Process meta data not available in database I am seeing above message and some warnings below..but don't have join stage though in the job.. Jn_Join_318: When checking operator: Dropping component "UPDATE_USER_ID" because of a prior co...
- Wed Oct 30, 2013 8:20 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: main_program: Fatal Error: Type mismatch for field 'ACCOUNT_
- Replies: 3
- Views: 4006
- Tue Oct 29, 2013 2:26 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: main_program: Fatal Error: Type mismatch for field 'ACCOUNT_
- Replies: 3
- Views: 4006
- Tue Oct 29, 2013 11:51 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: main_program: Fatal Error: Type mismatch for field 'ACCOUNT_
- Replies: 3
- Views: 4006
main_program: Fatal Error: Type mismatch for field 'ACCOUNT_
Hi ..
I am getting below warning..
main_program: Fatal Error: Type mismatch for field 'ACCOUNT_VALUE_ID'. Fatal error.
But couldn't find type match from the table and the job.
Any thoughts on how to find out or debug it?
Thanks!
I am getting below warning..
main_program: Fatal Error: Type mismatch for field 'ACCOUNT_VALUE_ID'. Fatal error.
But couldn't find type match from the table and the job.
Any thoughts on how to find out or debug it?
Thanks!
- Fri Oct 25, 2013 9:37 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Trim for Numeric/Decimals
- Replies: 2
- Views: 2831
- Fri Oct 25, 2013 9:00 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: When reading database column INT32 into column VARCHAR(min=0
- Replies: 1
- Views: 2842
When reading database column INT32 into column VARCHAR(min=0
Hi All , I am getting the following warning max_daily_position_id: Schema reconciliation detected a size mismatch for column KEY_LABEL. When reading database column INT32 into column VARCHAR(min=0,max=1), truncation, loss of precision or data corruption can occur. But KEY_LABEL is a dummy column wit...
- Wed Oct 23, 2013 10:10 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Trim for Numeric/Decimals
- Replies: 2
- Views: 2831
Trim for Numeric/Decimals
Hi ,
Is it ok to trim the Numeric/Decimal fields from a sequential file and load to Numeric/Decimal fields on target database?
Thanks
Is it ok to trim the Numeric/Decimal fields from a sequential file and load to Numeric/Decimal fields on target database?
Thanks
- Tue Oct 22, 2013 9:07 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Data string '20090102' does not match format '%yyyy-%mm-%dd'
- Replies: 10
- Views: 20249