Search found 16 matches

by Akhobare
Thu Jun 25, 2015 7:00 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: How NLS conversion helps?
Replies: 5
Views: 3246

Thanks Priyadarshi .. Will do some searching further on it.
by Akhobare
Wed Jun 24, 2015 12:48 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: How NLS conversion helps?
Replies: 5
Views: 3246

Any reply,hint,documentation pointer, please !!
by Akhobare
Tue Jun 23, 2015 5:42 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: How NLS conversion helps?
Replies: 5
Views: 3246

How NLS conversion helps?

Hi, I went through Datastage documentation on NLS use & setting , however couldn't get simple fact that how NLS setting helps in processing data which is in different character codes I read , - NLS mode works by using two types of character set: 1. The NLS internal character set 2. External char...
by Akhobare
Tue May 05, 2015 1:49 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Datastage Parallel Engine language
Replies: 4
Views: 2599

Thanks for quick reply.

( I will try to close the topic ( if allowed) if have no further doubts in couple of days).
by Akhobare
Sun Mar 20, 2011 11:42 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Teradata TPT Load method
Replies: 3
Views: 3143

np... I had reply from within the team and as per reply, read ( simple fetch or through SQLs) always completed prior to load. Besides while doing fastload (bulk --> load in append mode) orchstrate work table is created and loaded with data , then appended to target table. So there shouldn't be any i...
by Akhobare
Fri Mar 18, 2011 2:13 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Teradata TPT Load method
Replies: 3
Views: 3143

Can any one reply to above question?
by Akhobare
Thu Mar 17, 2011 4:14 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Teradata TPT Load method
Replies: 3
Views: 3143

Teradata TPT Load method

Hi , I need to confirmation about a case where i am fetching data from Teradata table and loading data into same table through TPT stage in same job. As of now , job is loading data without any misappropriation. What i understand TPT->Bulk->Load is fastLoad method. So it should create empty work tab...
by Akhobare
Mon Mar 07, 2011 12:55 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: File layouts & their import methods
Replies: 1
Views: 1257

File layouts & their import methods

Hi, Below is layout we were provided. I need some details on it. May be helpful for everyone here. RecordDef('RecordLevel1', Ref=RecordLevel1 ); Field('PathRidCode','X(1)', Ref=PathRidCode ); Field('PathRidCode','X(1)', Ref=PathRidCode ); Field('TicketNo','X(13)', Ref=TicketNo ); Field('TicketNoFill...
by Akhobare
Wed Aug 18, 2010 4:50 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calaculating ASCII value in datastage
Replies: 3
Views: 11466

The function you are looking for is SEQ(), which will return the numeric representation of the input single character, the function that returns a character given a numeric representation is CHAR(). Both can be looked up in the documentation and exist in both Server and Parallel versions. Thanks fo...
by Akhobare
Wed Aug 18, 2010 2:38 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calaculating ASCII value in datastage
Replies: 3
Views: 11466

Calaculating ASCII value in datastage

Hi, We need to get the ASCII values of incoming data to check whether they represent special chareacters. There seems to be function 'ASCII' and has couple of help pages in DataStage on that; but in tramsformer we are not able to use it. Transformer shows error like ' ASCII not defined.' So is it li...
by Akhobare
Wed Aug 11, 2010 6:12 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: CFF stage for reading EBCDIC file
Replies: 1
Views: 2194

CFF stage for reading EBCDIC file

Hi, I am novice to CFF satge and EBCDIC files.I m trying to read EBCDIC file through CFF stage. I set properties , Record Type= Fixed Char Set=EBCDIC Data Format = Binary Byte Order = Native Indian & then imported Pl/I definition. While viewing source data i am getting error, "error executi...
by Akhobare
Mon Jul 26, 2010 5:32 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: EBCDIC date issue
Replies: 4
Views: 4374

EBCDIC date issue

Hi, I am new to EBCDIC file format. I am reading EBCDIC file through Seq. file stage ( not CFF). Below properties are set : I referred exisitng simple jobs from our repository. character set : EBCDIC byte order : big-endian data format : binary Recod Type : implicit , delimiter : none. I have below ...
by Akhobare
Tue Jul 13, 2010 12:37 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Reading null & fixed width integers
Replies: 4
Views: 2956

Integers metadata properties Default=0 and Field Width=8 solved the problem.

Very simple but somehow i could'nt read it earlier.

Marking topic as Resolved.
by Akhobare
Mon Jul 12, 2010 6:05 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Reading null & fixed width integers
Replies: 4
Views: 2956

Reading null & fixed width integers

Hi , I am reading fixed-width file having integers. I have 2 requirements where, i> I need to read null value in Integer field ii> Should be able to read small integers in 8 digit format e.g. should be able to read '10' also in 8 width format. I have tried all permutation & combinations except t...
by Akhobare
Mon Jul 12, 2010 1:56 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Varying nature of job run
Replies: 7
Views: 5340

Not really an answer or even particularly true. :? What is the difference between the two runs, anything? Or did you literally run the job twice with no changes in the job or environment and get these two results? Your results are not identical as the problem has been reported by two different obje...