Chris,
poor choice of words for me. Mike thanks for the tip..
Baha
Search found 179 matches
- Thu Dec 18, 2008 12:09 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Functions and routines read only?
- Replies: 7
- Views: 2133
- Thu Dec 18, 2008 11:29 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Functions and routines read only?
- Replies: 7
- Views: 2133
Functions and routines read only?
Be gentle, i took a year off from DS world.
I see that functions and routines delivered with software is ready only now. (i.e you cannot see the code). Is that the norm with 8.0 or is it because the software was setup that way?
It was really helpful to see the code to generate other code..
I see that functions and routines delivered with software is ready only now. (i.e you cannot see the code). Is that the norm with 8.0 or is it because the software was setup that way?
It was really helpful to see the code to generate other code..
- Wed Dec 17, 2008 1:15 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: CFF and merging records back together
- Replies: 4
- Views: 1535
Craig, that also crossed my mind. Creating some stage var with SeqNum = SeqNum +1 type of derivation and an initial value of 1. I won't need to check the max value from the database as these records will be used one time and they will be for my internal processing. For some reason i remember this me...
- Wed Dec 17, 2008 12:32 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: CFF and merging records back together
- Replies: 4
- Views: 1535
CFF and merging records back together
I have a CFF stage that's receiving data from a COBOL copy book with REDEFINES and OCCURS clauses. (Brings back memories from old days). What i'd like to do is to produce some kind of a sequential record number so that i can match the records together later on. To give you an example here's the inpu...
- Mon Jun 04, 2007 4:36 pm
- Forum: IBM QualityStage
- Topic: Latitude and Longitude from address
- Replies: 1
- Views: 1765
- Wed Feb 28, 2007 4:33 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Varchar issues..
- Replies: 7
- Views: 2871
- Wed Feb 28, 2007 1:36 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Varchar issues..
- Replies: 7
- Views: 2871
- Wed Feb 28, 2007 1:32 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Varchar issues..
- Replies: 7
- Views: 2871
.... Use a constraint expression in the Transformer stage to direct rows where it is of the appropriate size onto one output link, and use a reject or alternative output link to capture the rows with an oversized column. Ray, that's fine and dandy when you are dealing with one or two columns of dat...
- Fri Feb 23, 2007 8:45 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Varchar issues..
- Replies: 7
- Views: 2871
Varchar issues..
I am reading Comma delimited file using Sequential file stage.I defined one column length as 20.But some times i am getting data for that column more than 20 like 25.Still the job is running by truncating the remaining 5 characters.Is there any way to check the length of the field dynamically? What ...
- Wed Mar 22, 2006 7:49 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Blanks in parameter values
- Replies: 2
- Views: 1245
- Wed Mar 22, 2006 6:36 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Blanks in parameter values
- Replies: 2
- Views: 1245
Blanks in parameter values
We just recently discovered that parameters supplied to dsjob scripts like InWord="Blanks are problem" create an issue. If the assignment is InWord="Blanksareproblem" it works fine. What would be the recommendation to solve this issue? (I did use the search function but couldn't ...
- Mon Dec 12, 2005 5:57 pm
- Forum: Site/Forum
- Topic: New Forum
- Replies: 11
- Views: 7899
- Wed Dec 07, 2005 6:22 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: filter operator requires more output ? Really?
- Replies: 4
- Views: 4976
filter operator requires more output ? Really?
This is the error I get from the Director: Filter_9,0: The filter operator requires more outputs than it has been configured for; it has 1, it needs 2. Why would it need 2 outputs? By the way, Output Rejects = False. When I change it to "True" and add a reject link out, it increases the va...
- Wed Nov 30, 2005 4:48 am
- Forum: Site/Forum
- Topic: Get moving folder for members :)
- Replies: 3
- Views: 3238
Get moving folder for members :)
Looking at the pictures from LV convention and looking at the mirror, i say we should open an area where we can talk about shedding some pounds/kilos
- Tue Nov 15, 2005 4:24 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: How to implement control break in PX?
- Replies: 8
- Views: 3673