Search found 78 matches

by tehavele
Fri Sep 18, 2009 9:46 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: This item has no design time information
Replies: 6
Views: 10103

This item has no design time information

Thank you guys for all the answers.I checked the Manager.I tried exporting one of jobs when i clicked on Job designs it said
"Unable to return an attached job."
So design time information is in the exported jobs.
Thanks once again for your responses. :)
by tehavele
Fri Sep 18, 2009 8:21 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: This item has no design time information
Replies: 6
Views: 10103

I guess it depends on what you consider 'useful'. You should at least have found out what it means and how you typically get there - it can either be a purposeful thing because you've only promoted released jobs or just the executables. If they were 'fine' before and suddenly started giving you thi...
by tehavele
Fri Sep 18, 2009 7:47 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: This item has no design time information
Replies: 6
Views: 10103

This item has no design time information

I am trying to open jobs in my project but getting the error
"This item has no design time information".
I tried searching for this topic but could not get anything useful. Could you help me resolve this issue links related to this topic will also do.Thanks in advance.
by tehavele
Thu May 07, 2009 11:52 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: DB2 Enterprise Stage - Truncate Option
Replies: 4
Views: 3365

Re: DB2 Enterprise Stage - Truncate Option

There is no specific truncate command in db2.
You can use following command in unix script.

Code: Select all

 import from /dev/null of del replace into #tablename#
Call that script in the before-job sub routine.
by tehavele
Tue Mar 31, 2009 11:36 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: lookup
Replies: 3
Views: 1958

Re: lookup

Did u search for ' sparse lookup ' ? This topic has been disscussed many times before.
by tehavele
Tue Mar 31, 2009 7:52 am
Forum: General
Topic: How to control the output of column in Column Generatorstage
Replies: 6
Views: 1407

Re: How to control the output of column in Column Generators

Make sure that new column (ID) is an integer one.
by tehavele
Tue Mar 31, 2009 7:50 am
Forum: General
Topic: How to control the output of column in Column Generatorstage
Replies: 6
Views: 1407

Re: How to control the output of column in Column Generators

Yes.Deifine the required field lets say as ID in the Column Generator Stage.In the OutPut page of this stage go to 'Edit Column Meta Data Box' by right clicking ID column and selecting 'Edit Row' option.Now in the 'Properties' option select 'Generator' box.Set 'Type=Cycle', Initial Value=1,Increamen...
by tehavele
Tue Mar 31, 2009 7:36 am
Forum: General
Topic: How to control the output of column in Column Generatorstage
Replies: 6
Views: 1407

Re: How to control the output of column in Column Generators

Absolutely.
Use 'Cycle' method.
Set Intial Value=1
Increament by = 0
by tehavele
Tue Mar 24, 2009 2:04 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Sequence generated in DB2
Replies: 8
Views: 3276

Hi, i didnt understand= 'Specifically you do not include the name of the key column in your design.' Am i not supposed to add my key column (The one i am doing NEXTVAL with ) in the columns property of my DB2 stage? It means INSERT INTO schema name .Table name ( col1,col2 ) VALUES ( NEXTVAL FOR sch...
by tehavele
Thu Mar 19, 2009 12:31 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job failure due to space
Replies: 9
Views: 3350

Re: Job failure due to space

I think instead of partitioning all 200mn rows in one go if we could partition those in chunks could resolve the space issue as 200mn rows worth space wont be required.Not sure on this.
by tehavele
Wed Mar 18, 2009 12:53 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job failure due to space
Replies: 9
Views: 3350

Re: Job failure due to space

Partition on 3 keys can be done on input links to funnel.Then Sort will have same partition method.


Regards,
Tejas
by tehavele
Wed Mar 18, 2009 12:46 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job failure due to space
Replies: 9
Views: 3350

Re: Job failure due to space

Hows the configuration file like ?
May be we can dedicate one node to sorting functionality alone.

Regards,
Tejas
by tehavele
Wed Mar 18, 2009 5:09 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Delete jobs from project .
Replies: 9
Views: 4420

thumati.praveen wrote:When i am trying to delete it is giving error message like (SOURCE OBJECT CANOT FOUND IN REPOSITORY )ANY body can help the same
Are you able to open that job in the designer ?