Thanks
This really helped..
Appreciated.. thanks again
Search found 12 matches
- Tue Dec 18, 2012 2:04 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Validate the string if in English
- Replies: 2
- Views: 1895
- Mon Dec 17, 2012 2:26 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Validate the string if in English
- Replies: 2
- Views: 1895
Validate the string if in English
Dear All
I'm trying to validate a string, which has arabic and English data in it..
If the data is in Arabic then pass '' else pass the column as is..
Could you'll pls help in this case.
Tried Alnum/Alpha, but doesn't work
I'm trying to validate a string, which has arabic and English data in it..
If the data is in Arabic then pass '' else pass the column as is..
Could you'll pls help in this case.
Tried Alnum/Alpha, but doesn't work
- Sun Jun 24, 2012 4:23 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: File created in server, needs to be read in parallel job
- Replies: 3
- Views: 3628
File created in server, needs to be read in parallel job
Hi Im trying to read a file which was created as a part of a server version, and has to be read now in the parallel version. At times i'm able to read the file, but when I run the job it gives me the below error. For example: Delimiter for field "MANDATE_INSTRUCTION" not found; input: {c7 ...
- Sun Jun 24, 2012 2:15 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: stringtoTimestamp
- Replies: 2
- Views: 2232
- Sat Jun 23, 2012 3:49 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: stringtoTimestamp
- Replies: 2
- Views: 2232
stringtoTimestamp
Hi Im trying to convert string to timestamp and I get the following error APT_CombinedOperatorController(2),2: Conversion error calling conversion routine timestamp_from_string data may have been lost the input column value from the sequential file is for example CRT_DATE 2006-03-15 19:39:12 I need ...
- Fri Oct 14, 2011 12:49 pm
- Forum: General
- Topic: Unable to Import DSX from 8.0 to 7.5
- Replies: 9
- Views: 6230
I want to confirm that a conversion here is possible. Some years ago I developed a Basic program to change the header, remove or replace several properties and adjust the category format in a DSX file, no matter if it was a Server or a Parallel export, or contained jobs, routines, shared containers...
- Fri Oct 14, 2011 12:42 pm
- Forum: General
- Topic: Unable to Import DSX from 8.0 to 7.5
- Replies: 9
- Views: 6230
- Fri Oct 14, 2011 6:46 am
- Forum: General
- Topic: Unable to Import DSX from 8.0 to 7.5
- Replies: 9
- Views: 6230
Unable to Import DSX from 8.0 to 7.5
Hi I have a dsx, which was on Datastage 8.0, on unix Now, I need to import this dsx into 7.5, and when i do so, I get the error. File C:\Baksh\TEMP\import.dsx does not appear to be a valid Datastage export file or is from an incompatible release. A valid DataStage export file is expected to be in Wi...
- Thu Sep 16, 2010 6:19 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Reset Sequence number
- Replies: 4
- Views: 2634
- Wed Sep 15, 2010 12:31 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Reset Sequence number
- Replies: 4
- Views: 2634
Reset Sequence number
Hi I have incoming data as Account Customer ----------- ------------- 1 A 1 B 1 C 1 D 2 E 2 F 5 W 5 V 5 L 5 I 5 P I want the sequence to be generated as Account Customer seq ----------- ------------- ---------- 1 A 1 1 B 2 1 C 3 1 D 4 2 E 1 2 F 2 5 W 1 5 V 2 5 L 3 5 I 4 5 P 5 That means.. for every ...
- Fri Jul 30, 2010 5:37 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job with Oracle Enterprise stage as the target hangs
- Replies: 2
- Views: 1691
- Fri Jul 30, 2010 12:57 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Getting Unable to insert a record due to.
- Replies: 8
- Views: 3781
Are you running the job through a sequencer or just the job or the script ? Suggestons Check if anywhere from the above you've defined the job to abort after certain row limit. Check if the admin or someone has set the limit in onsite. Also if its one to one load, try loading it through the sql alon...