Search found 20 matches
- Tue Dec 11, 2012 7:30 pm
- Forum: General
- Topic: DataStage project delete gone wrong
- Replies: 2
- Views: 1744
Re: DataStage project delete gone wrong
Thanks SURA. We think the approach would be to "Select & Wait" for extra minutes before proceeding with any action. We tried to delete another project by selecting it, waiting it and delete. It worked fine. Thanks for your help.
- Tue Dec 11, 2012 12:35 am
- Forum: General
- Topic: DataStage project delete gone wrong
- Replies: 2
- Views: 1744
DataStage project delete gone wrong
Hi, We deleted a DataStage project through "Infosphere DataStage Administration" window. We selected the right project and waited for project path to get populated(As it is bit slow) and then slected "Delete". What happened is, we selected project A to be deleted, but project B g...
- Wed Oct 03, 2012 8:16 pm
- Forum: General
- Topic: Export through command line(dsexport.exe)
- Replies: 2
- Views: 1858
- Tue Oct 02, 2012 1:07 am
- Forum: General
- Topic: Export through command line(dsexport.exe)
- Replies: 2
- Views: 1858
Export through command line(dsexport.exe)
Hi, I am using "dsexport.exe" to get a export dump of full project. This command takes only the job design and not the executables. The option "/EXEC" which helps to get only executables can be used in conjunction with "/JOB", so is there an option to get full project d...
- Fri Aug 31, 2012 12:52 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Phantom Error Unable to execute the operating system file
- Replies: 5
- Views: 3428
- Thu Aug 30, 2012 8:27 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Phantom Error Unable to execute the operating system file
- Replies: 5
- Views: 3428
- Wed Aug 29, 2012 11:50 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Phantom Error Unable to execute the operating system file
- Replies: 5
- Views: 3428
Phantom Error Unable to execute the operating system file
Hi, We have been getting this warning in Server job of 8.5 version. Irrespective of the server job, the error is as follows DataStage Job 348 Phantom 16719 Program "DSD.SendEvent": Line 524, Unable to execute the operating system file "-option01". [ENOENT] No such file or directo...
- Mon Jul 09, 2012 10:47 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Oracle Connector Stage
- Replies: 1
- Views: 1442
Oracle Connector Stage
Hi, This may be old question but asking it again, could not find in search. According to documentation the Oracle connector stage offers better functionality and performance replacing some stages which have been deprecated. Is there a real functionality difference in the way the oracle connector sta...
- Sun May 13, 2012 8:26 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Unable to insert records into oracle table
- Replies: 4
- Views: 2901
- Fri Aug 19, 2011 2:15 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Oracle Connector Stage
- Replies: 4
- Views: 4940
- Thu Aug 18, 2011 6:24 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Oracle Connector Stage
- Replies: 4
- Views: 4940
- Wed Aug 17, 2011 5:54 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Oracle Connector Stage
- Replies: 4
- Views: 4940
Oracle connector/Enterprise Stage
Hi, When using Oracle Connector for bulk loads(SQL Ldr, DIRECT=TRUE),do they create logs, in any place, either scratch disk or some directory ? Or do they store these information in any utility tables ? When using Enterprise Stage for Bulk loads, there are logs created in scratch disk locations ? Pl...
- Mon Apr 20, 2009 3:03 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Date Column in Lookup stage
- Replies: 1
- Views: 1089
Date Column in Lookup stage
Hi I am using Teradata stage as reference data for a Lookup stage. After key lookup between primary and referece stage, column extracted is DATE datatype. Problem -------- If lookup fails then, output DATE column is populating default date as "0001-01-01" Is that how the stage behaves for ...
- Wed Oct 01, 2008 5:08 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Teradata-Metadata upload error
- Replies: 1
- Views: 3584
Teradata-Metadata upload error
Hi I am using Teradata Multiload stage. in this using Plugin Metadata, I am trying to import some column metadata. As I am typing Teradata Directory , Username & Password, I am getting the following error. Unable to connect to Teradata Data Source SDMCUM. MTDP:EM_NOHOST(224):name not in HOSTS fi...
- Tue Sep 30, 2008 6:00 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Getting date -1 value
- Replies: 2
- Views: 1400
Getting date -1 value
Hi
I am passing a date parameter(22-10-2008) as an input to a column. I need, output as given date -1. I tried
date -1 in transformer stage, but job not getting compiled. Is this not the right way to get DATE -1 . How can this be achieved.
Thanks
I am passing a date parameter(22-10-2008) as an input to a column. I need, output as given date -1. I tried
date -1 in transformer stage, but job not getting compiled. Is this not the right way to get DATE -1 . How can this be achieved.
Thanks