calling multiinstance child sequence in multiinstc main seq
Hi Mentors, i am trying to achieve below things, but couldn't get idea. seq_child---> multiinstace seq_main--> multinstance seq_child have series of multiinstance job which i have parametized as #invocation_id# either INTL or DOM i am calling child in main, now seq_main one instance need to be run w...
- Fri Mar 18, 2011 4:49 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: How to calculate max in DS
- Replies: 4
- Views: 2082
- Thu Feb 24, 2011 11:05 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DB2 bulk load option..non recoverable
- Replies: 1
- Views: 3543
DB2 bulk load option..non recoverable
Hi All, i was just wondering non recoverable option in DB2 bulk load option.. i see the explationation "True indicates that your load transaction is marked as non-recoverable. It will not be possible to recover your transaction with a subsequent roll forward action. The roll forward utility wil...
- Thu Feb 17, 2011 3:23 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Importing parametrs from one project to another
- Replies: 4
- Views: 3256
- Thu Feb 17, 2011 3:19 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Dataset corruption, SIGSEGV while reading
- Replies: 21
- Views: 18756
check the enviorment in which you are reading it... since it partition it wont work on two different enviorment unless config file is same for both... i mean if you are reading dataset which created on 8-node config server to 4-node it won't work .... for that you should create new dataset on 4-node...
- Thu Feb 17, 2011 3:14 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: node contraints
- Replies: 12
- Views: 8120
@vidyut.. a single cpu can have multiple logical nodes as well as.... @ravi yes you can split in to two nodes by defining config file as you described but as cpu is one it won't improve performance of your job.. also data would be splitted on two nodes as you mentioned one with 10 node1 and 20 on no...
- Thu Feb 17, 2011 3:05 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Eliminate Duplicate data
- Replies: 5
- Views: 3094
you never said dupicate to be captured... there are many ways but one which i have tried ans tested sort the data using sort stage on key column which decide your duplicate.. then aggregate on same key. so you will have column value and count... now inner join input file with one the output from agg...
- Thu Feb 17, 2011 1:26 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Eliminate Duplicate data
- Replies: 5
- Views: 3094
- Tue Feb 15, 2011 3:43 am
- Forum: General
- Topic: connection between job and sequencer
- Replies: 4
- Views: 2572
- Wed Jan 12, 2011 12:23 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Spaces error at sequence level
- Replies: 12
- Views: 5126
- Tue Jan 11, 2011 4:59 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Spaces error at sequence level
- Replies: 12
- Views: 5126
- Tue Jan 11, 2011 12:41 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: ORA-00900: invalid SQL statement (Warning Message)
- Replies: 1
- Views: 2495
- Tue Jan 11, 2011 12:37 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Spaces error at sequence level
- Replies: 12
- Views: 5126
- Tue Jan 11, 2011 12:28 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Spaces error at sequence level
- Replies: 12
- Views: 5126
Hi Kirti, Thanks for quick reply... Have you tried using trip function? Also did you check the filename in job 4 and 5. May be the file is getting overwritten? I believ you reffering to strip function , i have already used this strip are you reffering to strip function , i have already used this str...