Search found 52 matches
- Wed Aug 12, 2009 5:15 am
- Forum: IBM QualityStage
- Topic: Record dropped during NULL handling
- Replies: 5
- Views: 29131
Re: Record dropped during NULL handling
in the transformer1 try function nulltovalue() for 'Exterior_MXADDR' and give some default value for the null. If the derivation column having null values..transformer wont allow. This may come under datastage problem i guess!! Vairamuthu The job looks like: Seq File1->Transformer1->Standardize->Tra...
- Tue Apr 07, 2009 12:10 am
- Forum: IBM QualityStage
- Topic: Reference Match Error
- Replies: 5
- Views: 4474
Re: Reference Match Error
Hi, Did you check the both DATA and REFERENCE frequency file ? Regards Hi, I developed Match Sepecification with one blocking field ( ID ) and one Matching field ( Name ). I created Frequency files with that Match Spec. When i ran the Reference Match job, I am getting the below error Reference_Match...
- Tue Mar 24, 2009 2:10 am
- Forum: IBM QualityStage
- Topic: MatchFrequency file Vs. the weightage
- Replies: 2
- Views: 2578
Re: MatchFrequency file Vs. the weightage
Hi, MatchFrequency file describe how often a value appears in source column. If a name appears 100 times in a column. MatchFrequency file output for that name will be a single row with number of occurance and statistical weight. So 200M records can generate lesser output records. In Matching process...
- Wed Mar 18, 2009 7:01 am
- Forum: Information Analyzer (formerly ProfileStage)
- Topic: Column Analysis - Format (NA)
- Replies: 0
- Views: 2781
Column Analysis - Format (NA)
Hi all, I did column analysis on a table . While reviewing the name column i found some data's are classified as 'NA' format. Only nulls ,spaces and whitespaces will be classified as "NA" format. Example of few data classified as 'NA': Somerset Hospital Nurses Residence Vodacom Container B...
- Mon Jan 05, 2009 3:17 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: warning 'delim=end' did not consume entire input
- Replies: 5
- Views: 26366
warning 'delim=end' did not consume entire input
Hi all, i write my unduplicate match and residula results in to a flat file. then i used those flat files as source to write in to the database. am getting warning while writing into the database message:initialday_match,0: Import consumed only 365bytes of the record's 375 bytes (no further warnings...
- Sun Jan 04, 2009 3:28 am
- Forum: IBM QualityStage
- Topic: Standardize data output
- Replies: 6
- Views: 6240
Re: Standardize data output
hi , When you writing output to the sequential file you have to set default null value. if you dont configure this you cant see any records in output file. Eventhough you can see status as success. it will apply to all jobs in datastage/qualitystage... regards Hi All. I have a question regarding Sta...
- Wed Dec 24, 2008 4:54 am
- Forum: IBM QualityStage
- Topic: Quality stage memory requirement
- Replies: 1
- Views: 2220
Re: Quality stage memory requirement
Hi ankita, The purpose of Ruleset is to parse the input data (standardization) only. The space for standardized data depends up on the number of rules you going to use. Test run with one million and find out the size of dataset file and make it for 150m . Better you can remove the standardization ou...
- Wed Dec 10, 2008 9:16 am
- Forum: IBM QualityStage
- Topic: Token Class: Table has duplicate entries
- Replies: 4
- Views: 3604
- Thu Nov 20, 2008 7:45 am
- Forum: Information Analyzer (formerly ProfileStage)
- Topic: Not able to save report as PDF file
- Replies: 4
- Views: 3766
- Thu Nov 20, 2008 7:41 am
- Forum: IBM QualityStage
- Topic: qualitystage best practices
- Replies: 2
- Views: 3387
- Thu Nov 20, 2008 2:17 am
- Forum: IBM QualityStage
- Topic: qualitystage best practices
- Replies: 2
- Views: 3387
qualitystage best practices
Hi guys,
Is there ibm best practice guides available for qualitystage8?
Could you tell me how to access that..
regards
vairamuthu
Is there ibm best practice guides available for qualitystage8?
Could you tell me how to access that..
regards
vairamuthu
- Mon Nov 10, 2008 3:23 am
- Forum: IBM QualityStage
- Topic: MatchFrequency problemwith more data
- Replies: 3
- Views: 5679
Hi rupesh, you dont have to free scratch space.. all the temp files neded the jobs are created in scratch space and then the processed data are written to dataset folders in dataset files.then the files in scratch folder are cleared by the sysem once the job is done. So you need to increase the size...
- Wed Nov 05, 2008 3:07 am
- Forum: Information Analyzer (formerly ProfileStage)
- Topic: Customizing report
- Replies: 3
- Views: 4043
- Tue Oct 28, 2008 7:51 am
- Forum: Information Analyzer (formerly ProfileStage)
- Topic: Customizing report
- Replies: 3
- Views: 4043
Customizing report
Hi , 1, How to customize a report in information analyzer .i.e adding a logo etc... 2, when we viewing the column analysis results. it displays like a dashboard with columnname uniqueness datatype dataclass format Is is possible to export or create this view as a report ? because IA report gives lot...
- Tue Oct 28, 2008 7:45 am
- Forum: Information Analyzer (formerly ProfileStage)
- Topic: info server :deleting a datasource
- Replies: 3
- Views: 3572