Search found 52 matches
- Wed Feb 27, 2008 2:26 am
- Forum: IBM QualityStage
- Topic: Automation of Qualitystage job from standardization to undup
- Replies: 5
- Views: 2812
Sequence job
Hi vcmburney, Thanks for your reply. I already gone through that redbook. It dint have example of it. i had a sample sequence job. But in that sample after standardization and frequency the next sequence job is undup .They dint include match specification in that sequence job. they include match spe...
- Mon Feb 25, 2008 3:29 am
- Forum: IBM QualityStage
- Topic: Automation of Qualitystage job from standardization to undup
- Replies: 5
- Views: 2812
Hai Ray, Thanks for your response . Could you please let me know the link ? It would be really nice if you give me the link ASAP... Thanks in advance Yes. One of the pictures in the glossy literature from IBM shows just such a job (for version 8). It even goes on to do survivorship in the same job. ...
- Mon Feb 25, 2008 1:49 am
- Forum: IBM QualityStage
- Topic: Automation of Qualitystage job from standardization to undup
- Replies: 5
- Views: 2812
Automation of Qualitystage job from standardization to undup
Hi All,
I would like to do
Standardization -> Frequency ->Match specification -> undup
like a sequential job..
Is there any way in qualitystage to do that?
I would like to do
Standardization -> Frequency ->Match specification -> undup
like a sequential job..
Is there any way in qualitystage to do that?
- Tue Feb 19, 2008 3:57 am
- Forum: IBM QualityStage
- Topic: Match specification running time?
- Replies: 0
- Views: 977
Match specification running time?
hi all,
Could any one please tell me where we could find the total running time of maching specification in qualitystage?
Thanks in Advance
Could any one please tell me where we could find the total running time of maching specification in qualitystage?
Thanks in Advance
- Mon Feb 18, 2008 8:03 am
- Forum: IBM QualityStage
- Topic: Matching error (not responding)
- Replies: 4
- Views: 2089
Re: Matching error (not responding)
hi
i added extra blocking column .Now matching specification runs. problem is single blocking colum.
Could you please tell me where we could find the total running time of maching specification in qualitystage?
thanks
vmcburney
i added extra blocking column .Now matching specification runs. problem is single blocking colum.
Could you please tell me where we could find the total running time of maching specification in qualitystage?
thanks
vmcburney
- Fri Feb 08, 2008 7:13 am
- Forum: IBM QualityStage
- Topic: Matching error (not responding)
- Replies: 4
- Views: 2089
thanks dude
am doing match(second pass) on registration number, year and type and i choose only a single blocking columns..i think thats tthe problem.
i ll create some more column for blocking in ruleset..
Thanks for the help vmcburney
i ll create some more column for blocking in ruleset..
Thanks for the help vmcburney
- Thu Feb 07, 2008 8:14 am
- Forum: IBM QualityStage
- Topic: Matching error (not responding)
- Replies: 4
- Views: 2089
Matching error (not responding)
Hi guys, i got error while running matching case. i had 3 passes.total rows 2.3 million. standardization file size is 6gb and frequency file is 2mb. system had 3 gb ram. paging size starting and ending is 2 gb. processor 3.5 ghz . i monitor the datasets .it finished first pass and it create empty .D...