Search found 72 matches

by udayk_2007
Wed Apr 28, 2010 3:07 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: can switch stage filter the null values?
Replies: 7
Views: 6321

I tried using word NULL in switch stage and it is working fine. With null, it doesn't work.
by udayk_2007
Fri Mar 05, 2010 4:55 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: datastage version upgrade
Replies: 2
Views: 2452

when running jobs on datastage version which is not installed on default port 31538,you have to also pass username and password in dsjob command
by udayk_2007
Mon Feb 01, 2010 11:48 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: issues due to datastage upgrade
Replies: 8
Views: 4940

Hello We also encountered similar issues when we upgraded from 7.5.1 to 7.5.3. some clues which we came to know while debuging were 1.While doing the update on the table, Datastage job was not using the table indexes implemented and performing full scan 2. Less number of db connections were getting ...
by udayk_2007
Tue Dec 29, 2009 11:21 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: DataStage not using the oracle table index
Replies: 2
Views: 1650

DataStage not using the oracle table index

Hi All We are migrating our environment from 7.5.1 to 7.5.3 ,and database is upgraded from Oracle 9i to Oracle 10g. Some of the jobs are getting hanged while updating in new environement (7.5.3 + 10g).After analysis with DBA Team,we come to know that jobs running on 7.5.3 ,are not using the oracle t...
by udayk_2007
Sat Oct 10, 2009 12:48 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Unable to write to file
Replies: 11
Views: 7798

May be you can check the space in /var directory of unix system.
by udayk_2007
Sun Aug 23, 2009 2:31 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: How to convert GMT to EST
Replies: 6
Views: 4343

If you are using Oracle as database,there is a in built function new_time which does the same function

e.g select new_time('15-Mar-09 14:35:00','GMT','EST) from dual;
by udayk_2007
Sun Aug 23, 2009 1:59 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Datastage Upgrade from 7.5.1 to 7.5.3
Replies: 4
Views: 2707

Thanks Chulett for your inputs :)

we are going with building a new server...Do you see any more things to be taken care in this scenerio :?:
by udayk_2007
Sat Aug 22, 2009 11:20 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Datastage Upgrade from 7.5.1 to 7.5.3
Replies: 4
Views: 2707

Datastage Upgrade from 7.5.1 to 7.5.3

Hi

We are planning to upgrade Datastage from 7.5.1 to 7.5.3 and database from oracle 9i to 10g....Does anybody faced any issues during this upgrade like any stage not working as expected etc.

Also like to know if any special precaution needs to be taken for the upgrade

Thanks
by udayk_2007
Sun Mar 29, 2009 2:38 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Unable to understand Datastage Director Warning
Replies: 5
Views: 3649

you are correct..putting 40 spaces is not the perfect solution ,its just a workaround to reduce warnings

your logic can be implemented in this case but it will require a transformer to put that code,which will hamper the job performance

Anyways...Thanks for your help
by udayk_2007
Sun Mar 29, 2009 1:38 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Unable to understand Datastage Director Warning
Replies: 5
Views: 3649

Hi

Thanks for your response

Actually i was getting that warning for reject files

now i have put 40 spaces in the null field value of those columns and the warning got resolved.
by udayk_2007
Sun Mar 29, 2009 12:20 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Unable to understand Datastage Director Warning
Replies: 5
Views: 3649

Unable to understand Datastage Director Warning

Hi I am getting following warning in Director Log FileName: When checking operator: When validating export schema: At field "Column_ABCD": "null_field" length (0) must match field's fixed width (40) Can anybody please suggest how can i get rid of this warning Thanks in advance
by udayk_2007
Wed Jun 04, 2008 1:24 pm
Forum: General
Topic: Getting Datastage Project names from Unix
Replies: 2
Views: 1865

Getting Datastage Project names from Unix

Hi Everybody

I want to get the Datastage Project names from unix server.Is there any unix command for it

Please help.Its urgent