this routine was exported as a read only..thatswhy we are getting this error.
As of now the project is in unprotected mode but we are not able to edit the routine...
what can be the solution....?
by z035011
Wed Aug 13, 2008 3:12 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Record <>in file DS_ROUTINES is read-only and cannot b
Replies: 4
Views: 1375

Record <>in file DS_ROUTINES is read-only and cannot b

I am trying to delete or rename one routine ...but I am getting the below error.

"Record <>in file DS_ROUTINES is read-only and cannot be rename"

I am using datastage admin ID ...
Can any one help me waht is the issue and how can i delete or edit the routine
by z035011
Thu Aug 07, 2008 6:23 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: LkupCalDim,0: Operator terminated abnormally: received signa
Replies: 0
Views: 482

LkupCalDim,0: Operator terminated abnormally: received signa

When I am running the job I am getting the below error ::
LkupCalDim,0: Operator terminated abnormally: received signal SIGSEGV

This datastage is running on SUN 5.8.

can anyone help me out here to resolve this issue?
by z035011
Thu Aug 07, 2008 2:51 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Failed to open RT_LOG2377 file
Replies: 10
Views: 2884

I run the command ps -ef | grep 2377 but there is no any process running...... I am not able to find the job in director so I cannot find the job PID and all the logs .... Actually I reindex the project itself not the job (my mistake I wrote the job) How can I move forward to comeup with this error....
by z035011
Wed Aug 06, 2008 8:09 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Failed to open RT_LOG2377 file
Replies: 10
Views: 2884

there is no any process with PID 2377.

Actually I have already reindexed the job before posting this topic.
by z035011
Wed Aug 06, 2008 8:06 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Failed to open RT_LOG2377 file
Replies: 10
Views: 2884

there is no any process with PID 2377.

Actually I have already reindexed the job before posting this topic.
by z035011
Wed Aug 06, 2008 6:31 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Failed to open RT_LOG2377 file
Replies: 10
Views: 2884

Failed to open RT_LOG2377 file

Hi, I tried to compile one job through designer then I got the error "Cannot get exclusive access to executable file for job <job_name> - job may be being monitored" . Then I unlocked all the jobs by command UNLOCK ALL. Again when I tried to run the job i got the error "Failed to open...
by z035011
Thu May 22, 2008 6:43 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Compilation error....
Replies: 12
Views: 5476

There si no any files ..under
/apps/Ascential/Projects/edw_stage/RT_BP4334.O>ls -l
total 0
by z035011
Thu May 22, 2008 6:10 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Compilation error....
Replies: 12
Views: 5476

yes files are there... /apps/Ascential/Projects/edw_stage/RT_SC4334>ls -l total 14 -rwxrwxr-- 1 dsadm dstage 644 May 22 04:59 OshExecuter.sh -rw-rw-r-- 1 dsadm dstage 3724 May 22 04:59 OshScript.osh -rwxrwxr-x 1 a035304 dstage 928 May 21 03:32 V0S166_ecf7003a2_TrmtemWebDesc.trx -rwxrwxr-x 1 a033988 ...
by z035011
Thu May 22, 2008 5:53 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Compilation error....
Replies: 12
Views: 5476

there is no any file under the same path.

/apps/Ascential/Projects/edw_stage/RT_BP4334>ls -l
total 0
by z035011
Thu May 22, 2008 4:31 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Compilation error....
Replies: 12
Views: 5476

Hi Arndw. below is the settings: Name prompt value APT_compileopt compiler option -dalign -O -PIC -library=iostream -c APT_compiler compiler /opt/SUNWspro/bin/CC APT_Linker Linker /opt/SUNWspro/bin/CC APT_linkopt linker options -G -library=iostream