Search found 138 matches
- Fri Sep 11, 2009 8:34 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: seqence warnings logs
- Replies: 6
- Views: 2068
seqence warnings logs
Hi I designed a Job Sequence , i used seqence between two Job activity stages and i had take two links "success" & "Warning", i ran the job . Job is working Fine. But i am getting some Warning like did not finish OK, status = 'Finish with warnings' I am thinking these warning...
- Wed Sep 09, 2009 11:38 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: "0x7c911982" referenced memory at "0x00000004
- Replies: 3
- Views: 1860
- Tue Sep 08, 2009 2:07 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: "0x7c911982" referenced memory at "0x00000004
- Replies: 3
- Views: 1860
"0x7c911982" referenced memory at "0x00000004
Hi
I am getting this error when i opend the Notification Stage.
The instruction at "0x7c911982" referenced memory at "0x00000004.The memory could not
Regards
surendro
I am getting this error when i opend the Notification Stage.
The instruction at "0x7c911982" referenced memory at "0x00000004.The memory could not
Regards
surendro
- Fri Sep 04, 2009 9:33 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: change_code in the input not found
- Replies: 1
- Views: 1504
change_code in the input not found
Hi I designed a job using change capture. The design is like this DB2API----| |==ODBC | | |==Change Capture==Transformer==| DB2API----| |==ODBC==ODBC In the Transformer i put the link constraint Lnk_Capture.change_code=3 or Lnk_Capture.change_code=1 for update and insert , Lnk_Capture.change_code=2 ...
- Mon Aug 24, 2009 12:09 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: warnings: No row was found for FETCH, UPDATE or DELETE
- Replies: 4
- Views: 1824
- Mon Aug 24, 2009 8:12 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: warnings: No row was found for FETCH, UPDATE or DELETE
- Replies: 4
- Views: 1824
warnings: No row was found for FETCH, UPDATE or DELETE
Hi I have a job that is delete the records in the target table. I am deleting two column records. Table Name -- It is a Primary Key Table SRKey -- It is a index key. When i ran the job it is through warning. No row was found for FETCH, UPDATE or DELETE; or the result of a query is an empty table. SQ...
- Thu Aug 20, 2009 9:52 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Array Size property will be set to 1
- Replies: 2
- Views: 3248
It was resolved.....
This issue is resolved... Array size. The input array size. The default is 50 rows that are cached before being written to the database. The array size value should be an integer greater than or equal to 1. Note: If a table that is being updated is also being used for reference lookups, the Array si...
- Thu Aug 20, 2009 9:36 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Array Size property will be set to 1
- Replies: 2
- Views: 3248
Array Size property will be set to 1
Hi
When i am load the records using Update existing or insert new rows.
Job is finished successfully. But i am getting warning.
This update action 'update or insert' is not compatible with parameter array binding. Array Size property will be set to 1.
When i am load the records using Update existing or insert new rows.
Job is finished successfully. But i am getting warning.
This update action 'update or insert' is not compatible with parameter array binding. Array Size property will be set to 1.
- Thu Aug 20, 2009 8:13 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: getting warnings when i am inserting records.
- Replies: 2
- Views: 1068
getting warnings when i am inserting records.
Hi The existing job is designed like this. Force source sequential files are club using Funel stage and insert in to target table. it is through warnings. That is why i was modifed the jobs after Funel stage i used change capture and insert the records to the target table. Sequential files -- Funel ...
- Mon Aug 17, 2009 7:46 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Preserve Partition error
- Replies: 2
- Views: 1516
- Wed Aug 12, 2009 11:45 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Preserve Partition error
- Replies: 2
- Views: 1516
Preserve Partition error
Hi When i design a job my source Advanced Tab details are Excutable Mode: default(sequential) Combinability Mode: Auto Preserve partition: Default(Propagate) ---------------------------------------------- Next Stage Advanced Tab details are Excutable Mode: default(Parallel) Combinability Mode: Auto ...
- Mon Aug 10, 2009 11:20 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Performance issue
- Replies: 12
- Views: 3869
- Mon Aug 10, 2009 11:20 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Performance issue
- Replies: 12
- Views: 3869
- Fri Aug 07, 2009 8:18 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Performance issue
- Replies: 12
- Views: 3869
- Thu Aug 06, 2009 7:19 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Performance issue
- Replies: 12
- Views: 3869
Performance issue
Hi I am reading source data and write in to target table using DB2 API stage. While writing data in to target table , deleting existing records from target table. It is a daily process. When i ask my lead why do not we truncate and load the data at traget table. They are not accepting. The existing ...