Search found 195 matches

by deesh
Thu Apr 23, 2009 2:54 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: WARNING ::APT_CombinedOperatorController(0),0:
Replies: 3
Views: 1901

Re: WARNING ::APT_CombinedOperatorController(0),0:

Hi Friends Below warning is giving problem to my job can any one give suggestion """APT_CombinedOperatorController(0),0: Field 'MBPUIT' from input dataset '0' is NULL. Record dropped."" but this field have data and lookup field also have data I given this condition in Trans...
by deesh
Thu Apr 23, 2009 2:09 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: WARNING ::APT_CombinedOperatorController(0),0:
Replies: 3
Views: 1901

WARNING ::APT_CombinedOperatorController(0),0:

Hi Friends
Below warning is giving problem to my job can any one give suggestion

"""APT_CombinedOperatorController(0),0: Field 'MBPUIT' from input dataset '0' is NULL. Record dropped.""


but this field have data and lookup field also have data
by deesh
Tue Apr 21, 2009 7:28 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: warning in the file
Replies: 1
Views: 647

warning in the file

Hi Friends, Can any one tell how to sove below warning APT_CombinedOperatorController,0: Invalid character(s) ([xDB]) found converting string (code point(s): PK[x03][x04][x14][x00][x00][x00][x08][x00][xDB]t[x90]:[xFD]*[x11][xAB];[x07][x00][x00][xE6][xD5][x00][x00]=[x00][x00][x00]OUT_DR0_0007_MCO_Mat...
by deesh
Mon Apr 20, 2009 8:01 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: file failure
Replies: 5
Views: 1571

Your metadata is incorrect and it's saying it can't find the record delimiter you said would be there. As noted, correct that. ... I have created the file in the previous job without using any record delimiter. I am running the jobs on windows 2003 server. The said job was running fine previously. ...
by deesh
Mon Apr 20, 2009 7:11 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Lookup not working
Replies: 8
Views: 1888

Re: Lookup not working

deesh wrote:Hi Friends,

When I am look uping data, look up is not working, data is coming as null but data is there, Moreover job is not showing any warning and failures.
I am prepared same condition for two jobs but one job is working, second one is not working i given same conditions but not working.
by deesh
Mon Apr 20, 2009 7:09 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: file failure
Replies: 5
Views: 1571

file failure

Hi Friends,

I am phasing below failure.

SEQ_SAP_FILE,0: Consumed more than 100000 bytes looking for record delimiter; aborting
by deesh
Sun Apr 19, 2009 6:55 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Implement logic
Replies: 1
Views: 789

Implement logic

Hi Friends Can Help to me How to implement below logic. I Taken Lookup and given reference key L _ID=LSN It will generate values If it is not have value how to implement 'kkkk' Value in transformer, I am confused in this. Logic ""To convert O_ID zone, read the conversion table with key L_I...
by deesh
Sun Apr 19, 2009 6:49 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Lookup not working
Replies: 8
Views: 1888

Re: Lookup not working

deesh wrote:Hi Friends,

When I am look uping data, look up is not working, data is coming as null but data is there, Moreover job is not showing any warning and failures.
---Its Varchar
by deesh
Sat Apr 18, 2009 2:01 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Lookup not working
Replies: 8
Views: 1888

Re: Lookup not working

Hi Friends, When I am look uping data, look up is not working, data is coming as null but data is there, Moreover job is not showing any warning and failures. """ I given Continue option""" In the same lookup I given two reference keys from two tables Table1 Table2 1. ...
by deesh
Fri Apr 17, 2009 10:42 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Lookup not working
Replies: 8
Views: 1888

Lookup not working

Hi Friends,

When I am look uping data, look up is not working, data is coming as null but data is there, Moreover job is not showing any warning and failures.
by deesh
Fri Apr 17, 2009 6:25 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Look_up warning
Replies: 5
Views: 3530

Look_up warning

Hi Friends,
I am encountering the Lookup warning can tell to me the solvation This data coming from SQL Server


Lookup_140,0:Ignoring duplicate entry at table record 3; no further warnings will be issued for this table
by deesh
Thu Apr 16, 2009 7:04 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Decimal warning
Replies: 2
Views: 1067

Decimal warning

Hi Friends, When I am sending data to Rejects file it showing below warning can tell to me how solve this warning. This "LOSGR" Having Decimal Datatype, Size is 13,3. REJECTS: When checking operator: When validating export schema: At field "LOSGR": "null_field" length (...
by deesh
Tue Apr 14, 2009 8:30 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Somebody accessed my job how delete their access
Replies: 1
Views: 983

Somebody accessed my job how delete their access

Hi,
one of my coleague accessed my job for reference suddenly datastage has shutdown, when I reopen It showing MR.'X'has accessed the job, but actually he is also unable to access the job how to access my job. Please help to me.
by deesh
Tue Apr 14, 2009 7:39 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: UN IDENTIFIED ERROR
Replies: 1
Views: 739

UN IDENTIFIED ERROR

HI FRIENDS, I am generating report with datastage, In Aggregator I given One group only, but instead of one row it generating two rows. Example: I Given "Job Name ", "START_TIME", Its generating each one two times instead of one time TR--AGG--JN---TR--ODBC........ This is the flo...
by deesh
Thu Apr 09, 2009 6:41 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Union operator problem
Replies: 6
Views: 5747

SAP Table having only 98 rows but Another table have more than 20000 rows how to use unique key for this.