Search found 20 matches
- Wed Apr 01, 2009 7:20 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Getting type conversion warning when transforming data
- Replies: 1
- Views: 1311
Getting type conversion warning when transforming data
Hi, I am getting type conversion warning when transforming data from table to table. I have used SCD stage and the data type are varchars only. I am getting a warning like this. Can anyone please tell me what would be the problem. Thanks in advance. ##I IIS-DSEE-TFCN-00001 12:50:41(000) <main_progra...
- Wed Jan 28, 2009 4:27 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Many instances of OSH.exe
- Replies: 2
- Views: 3595
Many instances of OSH.exe
Hi,
We are getting many instances of osh.exe on the server. Can we delete them..? please explain about this...
Regards
Rudresh
We are getting many instances of osh.exe on the server. Can we delete them..? please explain about this...
Regards
Rudresh
- Wed Oct 22, 2008 5:53 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Project Not found in Desginer
- Replies: 4
- Views: 1765
Hi, Thanks for the reply. We got there but it did not help. We got to the datastage credentials and then chose our server. We are not using a shared registry. We tried changing the password of one of the usernames and then through Client aministrator/ designer tried logging in. It did not allow and ...
- Wed Oct 22, 2008 4:50 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Project Not found in Desginer
- Replies: 4
- Views: 1765
Project Not found in Desginer
Hi, Got a strange problem here. We were not able to log into the project as it said the username/Password are invalid. Then , on web console we chnaged the password for the username under 'user group' tab. Still the condition is the same. The repository DB is already up and many files exists under t...
- Wed Oct 01, 2008 3:45 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Nulls appear for business key columns on SCD Type1 update
- Replies: 11
- Views: 4975
- Wed Oct 01, 2008 3:13 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Nulls appear for business key columns on SCD Type1 update
- Replies: 11
- Views: 4975
Nulls appear for business key columns on SCD Type1 update
Hi, I am using SCD stage to do type 1 updates on a particular table.The business key field is of type varchar. When changes on the attribute takes place instead of update a new row is inserted but with business key value NULL. I tried changing the datatype from varchar to integer (since value were c...
- Thu Sep 11, 2008 4:17 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job Monioring fails in designer
- Replies: 6
- Views: 2927
Job Monioring fails in designer
Hi, On execution the job succeeds with status as OK. The data inserted is also fine. But in the designer, While executing, no information on the number of rows inserted is displayed. there is one warning in the director log, Main_Program:Failed to initialize job monitoring. Monitor information will ...
- Wed Sep 10, 2008 3:21 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Using Env variables in SCD stage
- Replies: 3
- Views: 2307
- Tue Sep 09, 2008 9:30 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Using Env variables in SCD stage
- Replies: 3
- Views: 2307
Using Env variables in SCD stage
Hi, i want to parameterise the filenames in the SCd stage where, for surrogate key generation a flat file is used and the source name is set to the name of the file using which this key is generated. I used a ENV variable for filename and there was a compilattion error. But when using a job paramete...
- Mon Sep 08, 2008 3:00 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Performance tuning for SCD Stage
- Replies: 1
- Views: 1315
Performance tuning for SCD Stage
Hi All,
I have created a job with SCD stage. The target is ODBC Enterprise stage (For SQL Server). For around 50,000 records, it is taking 7+ minutes. Can we do any more tuning to make it less than that time?
Thanks in Adv.
Regards
Rudresh
I have created a job with SCD stage. The target is ODBC Enterprise stage (For SQL Server). For around 50,000 records, it is taking 7+ minutes. Can we do any more tuning to make it less than that time?
Thanks in Adv.
Regards
Rudresh
- Thu Aug 28, 2008 11:36 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Many Jobs in a sequence Abort, when executed in parallell
- Replies: 4
- Views: 6318
Many Jobs in a sequence Abort, when executed in parallell
Hi, I have 5 sequences, each one of them has many jobs and most of these jobs are to be executed simultaneously in parallell. When the 5th sequence which has the other 4 sequences in it is executed, it can be observed in the director that 6-10 jobs execute at the same time. This does not affect the ...
- Thu Aug 21, 2008 5:08 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Float Datatype handling - Conversion from dfloat to sfloat
- Replies: 5
- Views: 3519
- Thu Aug 21, 2008 2:18 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Float Datatype handling - Conversion from dfloat to sfloat
- Replies: 5
- Views: 3519
- Wed Aug 20, 2008 9:40 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Float Datatype handling - Conversion from dfloat to sfloat
- Replies: 5
- Views: 3519
Float Datatype handling - Conversion from dfloat to sfloat
If there is a float field in the destination, i am getting the below error. APT_CombinedOperatorController(1),1: Fatal Error: Accessor type "sfloat" does not match interface field type "dfloat". If i convert it into integer, it works. But i need to convert it in to float datatype...
- Wed Apr 30, 2008 3:40 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Is there any function for converting single to double byte
- Replies: 9
- Views: 5613