Search found 246 matches
- Tue Jun 26, 2007 10:55 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Teradata aborts half way through
- Replies: 5
- Views: 3899
1. No u cannot change how TD handles data distribution. if u have 96 AMPS it will distribute data on them using its own hashing algos. If u think all data is on one amp it means there is a serious skew factor in ur data i.e. non uniqueness and kills the basic theory of parallelism when it comes to d...
- Mon May 28, 2007 4:31 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Input dataset does not have field
- Replies: 0
- Views: 849
Input dataset does not have field
Hi all , well i know this was discussed before but that guy who posted it for the first time just said at one point its working now and dint bother giving the solution.. i am having the same problem when i work with dataset.. i am just testing the compress stage Dataset---->> Compress stage---->>> d...
- Mon May 21, 2007 11:49 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Node configuration
- Replies: 2
- Views: 1463
Node configuration
Hi all, Is it possible to write a config file which has two nodes and each node pertains to two different servers.. that is if i have two servers S1 and S2 .. can i write a config file ABC with nodes N1 and N2 .. where N1 has procesing power of and uses disk storage of S1 and N2 and processing power...
- Mon May 14, 2007 4:23 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: APT_TeraSync: connecting to Teradata ?
- Replies: 5
- Views: 3552
APT_TeraSync: connecting to Teradata ?
I am attempting to both read and load to the same view of a table within a DataStage job, using Multiload and getting an error which DataStage gives as "APT_TeraSync: could not create operator sync table".
any ideas ?
any ideas ?
- Fri May 11, 2007 5:50 am
- Forum: General
- Topic: Connectivity problems
- Replies: 2
- Views: 1770
Connectivity problems
just a general question about DS connectivity.. when i try to run DS on local machine without LAN connectivity it fails to connect.... .any ideas '? do i need to install any loop back patches ?
thanks
thanks
- Mon May 07, 2007 4:02 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Teradata Multiload stage Failure
- Replies: 3
- Views: 2925
- Fri May 04, 2007 5:31 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Teradata Stages
- Replies: 4
- Views: 2148
- Wed May 02, 2007 10:16 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Teradata Stages
- Replies: 2
- Views: 1740
- Wed May 02, 2007 10:04 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Job import issues
- Replies: 2
- Views: 1260
Job import issues
i just tried importing a job which i exported from another machine running datastage on the same OS, i am getting the following two issues. 1. job can only be imported when the client code page is 1256 . currently it is 1252. 2. incompatible release or the file is expteced to be in windows format an...
- Thu Apr 26, 2007 3:51 am
- Forum: General
- Topic: DataStage XML Pack Guide
- Replies: 2
- Views: 3164
DataStage XML Pack Guide
Does any one has this documentation please ? i would appreciate if you can send it to me as i really need it
if it can be mailed at: spicy_clumsy@hotmail.com
Many thanks , much appreciated
if it can be mailed at: spicy_clumsy@hotmail.com
Many thanks , much appreciated
- Tue Apr 24, 2007 1:32 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: DS administrator help !
- Replies: 6
- Views: 1778
Ascential recommends you do not install Windows XO SP2 on a machine running the DataStage Client software at this time. Windows XP SP2 was released publicly by Microsoft on August 16th, 2004. Microsoft has since published several lists of over 100 applications from 3rd party software vendors that ha...
- Tue Apr 24, 2007 12:35 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: DS administrator help !
- Replies: 6
- Views: 1778
- Mon Apr 23, 2007 11:57 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: DS administrator help !
- Replies: 6
- Views: 1778
- Mon Apr 23, 2007 11:34 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: unable to pad zero on left side
- Replies: 6
- Views: 4123
Try the string function .. something like this .. i have done it and worked for me Str(string, number of times to be repeated) i.e. STR('0', 3): FieldName woud pad three zeros to the left of FieldName so if you write somethin like STR('0', Length of Actual field - Len(Link.ActualField) : Actualfield...
- Mon Apr 23, 2007 11:23 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: DS administrator help !
- Replies: 6
- Views: 1778
DS administrator help !
Hi, i have some problems when i try to view the properties of a particular project. i log in as a admin . am able to create a project . but its just does nothing and goes to non responding when it come to the properties view ? just wondering are there any particular check list i need to go through t...