Hello,
in parallel i tried with CFF stage,
i also used the cobol copy book definitions and got erros like:
Complex_Flat_File_14,0: Field "JNAFOC_DATCRE" has import error and no default value; data: {o c1 c3 c7}, at offset: 1
Search found 55 matches
- Fri Jun 11, 2010 3:13 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: reading ebcdic data
- Replies: 5
- Views: 1694
- Thu Mar 11, 2010 1:02 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job control process (pid xxxxx) has failed
- Replies: 9
- Views: 14154
- Wed Mar 10, 2010 7:37 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job control process (pid xxxxx) has failed
- Replies: 9
- Views: 14154
- Wed Mar 10, 2010 7:29 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job control process (pid xxxxx) has failed
- Replies: 9
- Views: 14154
- Wed Mar 10, 2010 4:13 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job control process (pid xxxxx) has failed
- Replies: 9
- Views: 14154
- Wed Mar 10, 2010 1:00 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job control process (pid xxxxx) has failed
- Replies: 9
- Views: 14154
- Tue Mar 09, 2010 10:31 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Job control process (pid xxxxx) has failed
- Replies: 9
- Views: 14154
Job control process (pid xxxxx) has failed
Sometimes (e.g. today) jobs fail with the message: Job control process (pid xxxxx) has failed. I have searched through this forum, have read dozends of posts. But nothing really gave me an answer. Let me desribe what i see: Today 3 Jobs show this problem. It is the first run of this jobs after re-st...
- Tue Mar 09, 2010 10:19 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Column ... floating point decimal is not fully supported;
- Replies: 11
- Views: 5340
- Mon Mar 08, 2010 9:21 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Column ... floating point decimal is not fully supported;
- Replies: 11
- Views: 5340
Move Message Handler Files
Hello, well, meanwhile i have manual demoted many warnings to informational on the new Test-Maschine. I find now many ".msh" Files there: dsuser@dwhsie1u /datastage # find . -name *.msh -print ./Ascential/DataStage/Projects/DEV_EDW/RT_SC139/Local.msh ./Ascential/DataStage/Projects/DEV_EDW/...
- Mon Mar 08, 2010 4:49 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Column ... floating point decimal is not fully supported;
- Replies: 11
- Views: 5340
Migration of the Message Handler
Hello Ray,
well, Datastage Source have been migrated to a new system.
But not the Message-Handler.
How could i do this ???
Manfred
well, Datastage Source have been migrated to a new system.
But not the Message-Handler.
How could i do this ???
Manfred
- Tue Mar 02, 2010 3:50 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Column ... floating point decimal is not fully supported;
- Replies: 11
- Views: 5340
Thanks for your feedback. But this sounds like to make changes in Datastage on Job level. As the jobs run properly in the old environment, but now i get in dozends of jobs 100s of warinings, i think there is a very general parameter issue anywhere in Datstage, Unix or Oracle which has to be changed,...
- Tue Mar 02, 2010 1:27 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Column ... floating point decimal is not fully supported;
- Replies: 11
- Views: 5340
Column ... floating point decimal is not fully supported;
Hello, i found many entries in the forum regarding this topic, but nothing for my special problem: We change out environement from HP to AIX, and of course get Oracle new installed. On the new maschine all jobs reading from oracle now get this messages "Column ... floating point decimal is not ...
- Wed Dec 16, 2009 2:26 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Failed to connect to JobMonApp on port 13401
- Replies: 5
- Views: 7780
Hello, thanks for your replay. 1. APT_ORCHHOME: how should i set this? You really think, this parameter is related to JobMonitor? 2. netstat -a |grep dsrpc | wc -l shows: 1 So, i still don't really know, how to get the JobMonitor runing. Just to mention again, JobMonitor was runing in the past, and ...
- Mon Dec 14, 2009 8:01 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Failed to connect to JobMonApp on port 13401
- Replies: 5
- Views: 7780
- Mon Dec 14, 2009 4:11 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Failed to connect to JobMonApp on port 13401
- Replies: 5
- Views: 7780
Failed to connect to JobMonApp on port 13401
Since Today i get the warning: Failed to connect to JobMonApp on port 13401 I know, that there are alredy many posts on this issue. I think, i have read most of them. I stopped and re-started the JobMonitor several times. I stopped and re-started Datastage several times. I used "ipcrm" and...