Search found 55 matches

by Manfred Hagedorn
Fri Jun 11, 2010 3:13 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: reading ebcdic data
Replies: 5
Views: 1694

Hello,
in parallel i tried with CFF stage,
i also used the cobol copy book definitions and got erros like:
Complex_Flat_File_14,0: Field "JNAFOC_DATCRE" has import error and no default value; data: {o c1 c3 c7}, at offset: 1
by Manfred Hagedorn
Thu Mar 11, 2010 1:02 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job control process (pid xxxxx) has failed
Replies: 9
Views: 14154

Hello,
well, i set PX_DEBUG=1 and the job failure happend again.
But i don't see anything more in the logs now, or?
Manfred
by Manfred Hagedorn
Wed Mar 10, 2010 7:37 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job control process (pid xxxxx) has failed
Replies: 9
Views: 14154

Hello,
thanks a lot!
I understand, that this parameter is, to get more log informations for this PID-Error.
As the jobs are currently running (anyhow), i will set this parameter when this issue comes up next time.

I will leave this open so long (and definitly update it later).

Manfred
by Manfred Hagedorn
Wed Mar 10, 2010 7:29 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job control process (pid xxxxx) has failed
Replies: 9
Views: 14154

Hello,
sorry, where to set PS_DEBUG?
And then?
Manfred
by Manfred Hagedorn
Wed Mar 10, 2010 4:13 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job control process (pid xxxxx) has failed
Replies: 9
Views: 14154

Hello, no, we don't get timeouts. System is runing fine since months. Only this problem exists. For your information a put here some output of the logs form &PH&: DataStage Job 2338 Phantom 570 CRITICAL ERROR! Notify the system administrator. DataStage Job 2330 Phantom 15605 Program "DS...
by Manfred Hagedorn
Wed Mar 10, 2010 1:00 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job control process (pid xxxxx) has failed
Replies: 9
Views: 14154

Hello,
after further testing, meanwhile my most favorite approach seems to be a change of AptConfig (means a change/reduction of nodes).
Can anybody agree to this and tell we why???
Manfred
by Manfred Hagedorn
Tue Mar 09, 2010 10:31 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Job control process (pid xxxxx) has failed
Replies: 9
Views: 14154

Job control process (pid xxxxx) has failed

Sometimes (e.g. today) jobs fail with the message: Job control process (pid xxxxx) has failed. I have searched through this forum, have read dozends of posts. But nothing really gave me an answer. Let me desribe what i see: Today 3 Jobs show this problem. It is the first run of this jobs after re-st...
by Manfred Hagedorn
Tue Mar 09, 2010 10:19 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Column ... floating point decimal is not fully supported;
Replies: 11
Views: 5340

Super,
thanks for the hint to the IBM patch!
Manfred
by Manfred Hagedorn
Mon Mar 08, 2010 9:21 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Column ... floating point decimal is not fully supported;
Replies: 11
Views: 5340

Move Message Handler Files

Hello, well, meanwhile i have manual demoted many warnings to informational on the new Test-Maschine. I find now many ".msh" Files there: dsuser@dwhsie1u /datastage # find . -name *.msh -print ./Ascential/DataStage/Projects/DEV_EDW/RT_SC139/Local.msh ./Ascential/DataStage/Projects/DEV_EDW/...
by Manfred Hagedorn
Mon Mar 08, 2010 4:49 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Column ... floating point decimal is not fully supported;
Replies: 11
Views: 5340

Migration of the Message Handler

Hello Ray,

well, Datastage Source have been migrated to a new system.
But not the Message-Handler.
How could i do this ???

Manfred
by Manfred Hagedorn
Tue Mar 02, 2010 3:50 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Column ... floating point decimal is not fully supported;
Replies: 11
Views: 5340

Thanks for your feedback. But this sounds like to make changes in Datastage on Job level. As the jobs run properly in the old environment, but now i get in dozends of jobs 100s of warinings, i think there is a very general parameter issue anywhere in Datstage, Unix or Oracle which has to be changed,...
by Manfred Hagedorn
Tue Mar 02, 2010 1:27 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Column ... floating point decimal is not fully supported;
Replies: 11
Views: 5340

Column ... floating point decimal is not fully supported;

Hello, i found many entries in the forum regarding this topic, but nothing for my special problem: We change out environement from HP to AIX, and of course get Oracle new installed. On the new maschine all jobs reading from oracle now get this messages "Column ... floating point decimal is not ...
by Manfred Hagedorn
Wed Dec 16, 2009 2:26 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Failed to connect to JobMonApp on port 13401
Replies: 5
Views: 7780

Hello, thanks for your replay. 1. APT_ORCHHOME: how should i set this? You really think, this parameter is related to JobMonitor? 2. netstat -a |grep dsrpc | wc -l shows: 1 So, i still don't really know, how to get the JobMonitor runing. Just to mention again, JobMonitor was runing in the past, and ...
by Manfred Hagedorn
Mon Dec 14, 2009 8:01 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Failed to connect to JobMonApp on port 13401
Replies: 5
Views: 7780

Hello Chulett, First "netstat -a |grep 13401" showed nothing. After restarting Datastage again, it shows: tcp 0 0 *.13401 *.* LISTEN But Warning still is in the log. Beside the message mentioned in the header, there is in the log: Contents of phantom output file => DataStage Job 1204 Phant...
by Manfred Hagedorn
Mon Dec 14, 2009 4:11 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Failed to connect to JobMonApp on port 13401
Replies: 5
Views: 7780

Failed to connect to JobMonApp on port 13401

Since Today i get the warning: Failed to connect to JobMonApp on port 13401 I know, that there are alredy many posts on this issue. I think, i have read most of them. I stopped and re-started the JobMonitor several times. I stopped and re-started Datastage several times. I used "ipcrm" and...