ArndW wrote:Avik - you neglected to tell us what database you wish to connect to....
Search found 41 matches
- Wed Dec 19, 2007 3:31 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Direct native connection or ODBC(Where to specify)
- Replies: 2
- Views: 774
- Wed Dec 19, 2007 2:49 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Direct native connection or ODBC(Where to specify)
- Replies: 2
- Views: 774
Direct native connection or ODBC(Where to specify)
Hi,
I will be intalling a Datastage server in a fresh system.
I want to know where can I specify whether ODBC or direct native connection will be used for connecting to remote database.
Thanks and Regards
Avik Dasgupta
I will be intalling a Datastage server in a fresh system.
I want to know where can I specify whether ODBC or direct native connection will be used for connecting to remote database.
Thanks and Regards
Avik Dasgupta
- Tue Dec 18, 2007 11:54 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: changes required for new Db2 database connection
- Replies: 0
- Views: 423
changes required for new Db2 database connection
Hi All, My datastage server was preveiously pointing to a DB2 database which was installed in a separate system. Now the same database will be installed in the same machine where the datastage server is installed.Everything regarding the database will remain the same i.e database name ,database inst...
- Mon Sep 24, 2007 10:58 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Increasing heap memory allocation
- Replies: 1
- Views: 933
Increasing heap memory allocation
Hi, We faced following error while running a job. Join_36,5: The current soft limit on the data segment (heap) size (805306368) is less than the hard limit (2147483647), consider increasing the heap size limit Join_36,5: Current heap size: 276,559,192 bytes in 13,936 blocks Join_36,5: Failure during...
- Mon Sep 24, 2007 10:51 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Error in transformer stage:decimal value out of integer rang
- Replies: 2
- Views: 1862
- Thu Sep 20, 2007 2:54 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Error in transformer stage:decimal value out of integer rang
- Replies: 2
- Views: 1862
Error in transformer stage:decimal value out of integer rang
Hi, We are extracting data from OLTP oracle table into Dataset. In oracle table some columns are their which are of Decimal data type. There is a transformer stage between oracle stage and dataset stage. In the transformer we are converting decimal data type to intrger data type. Though every thing ...
- Tue Sep 18, 2007 7:58 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Problem in accessing DB2 database through DB2enterprisestage
- Replies: 1
- Views: 856
Problem in accessing DB2 database through DB2enterprisestage
Hi, Previously our datastage server was accessing another db2 server. Now it will access a separete db2 database. We have user ,necessary privilleges . We are also able to connect to the new db server from our datastage server from OS level. But when we are trying to access the db2 server from DB2 e...
- Fri Sep 14, 2007 2:30 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: How to get process id of job
- Replies: 4
- Views: 12684
Re: How to get process id of job
Hi, But I am not able to login to Dastage Director.I want to get the process id directly from operating systems from datastage director goto cleanup resources there u can get the procees ids for particular jobs.due to those ids u can kill the jobs. Hi, I want to kill all running jobs in a project. B...
- Fri Sep 14, 2007 2:07 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: How to get process id of job
- Replies: 4
- Views: 12684
How to get process id of job
Hi, I want to kill all running jobs in a project. But I am unable to login to datastage client,if any case I am able to log in and trying to abort the job the server is not responding. So I want to kill the jobs from operating system. How can I get the process Ids of running jobs. I want to go in fo...
- Tue Sep 04, 2007 11:04 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Repository Indexing
- Replies: 1
- Views: 754
Repository Indexing
Hi All, Can you plz explain what is repository indexing and why rebuilding of index is required? This topic I could not find in the manual.I tried to find in this forum also, but could not find the detail explanation.I need to know this because I need to reindex for a project.Plz help. Thanks in adv...
- Tue Sep 04, 2007 12:59 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Error in opening project(subroutine failing)
- Replies: 1
- Views: 731
Error in opening project(subroutine failing)
Hi, I have a project named RAS_PH1_WLESS_ADM. Whenever I am trying to log in to the project though it is opening it is showing a error: Error Calling Subroutine:DSR_EXECJOB(Action=5);check datastage is set up correctly in project RAS_PH1_WLESS_ADM (Subroutine failed to complete successfully(30107))....
- Thu Aug 30, 2007 5:26 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: One configuration file for multiple projects
- Replies: 4
- Views: 1235
- Thu Aug 30, 2007 3:40 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: One configuration file for multiple projects
- Replies: 4
- Views: 1235
- Thu Aug 30, 2007 3:21 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: One configuration file for multiple projects
- Replies: 4
- Views: 1235
One configuration file for multiple projects
Hi,
Will there be any problem if one configuration file is used for multiple
projects in a single Datastage server?
Will there be any problem if one configuration file is used for multiple
projects in a single Datastage server?
- Mon Aug 27, 2007 5:38 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Problem in stopping Datastage server
- Replies: 5
- Views: 5933
Hi , Thanks for your reply. You have suggested that we can unlock all CLOSE_WAIT states logging as dsadm.Does it mean releasing all the tcp sockets in CLOSE_WAIT state? Regards Avik Definitely not the right way of restarting datastage. CLOSE_WAIT states are waiting to close. You could wait a while a...