Search found 194 matches

by dsscholar
Thu Apr 07, 2011 11:33 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: RDBMS code 3807: Object does not exist.Updating in teradata
Replies: 0
Views: 4623

RDBMS code 3807: Object does not exist.Updating in teradata

i am Using Teradata connector stage in Target ,seeting there is access Method is BULK ,configured all the bulk seeting in the teradata stage , Trying to update a view of a table ,nearly 1.4 million rows need to update in the After sql i am collecting stats on the table and expilicitly supplying the ...
by dsscholar
Wed Jun 10, 2009 11:44 am
Forum: IBM QualityStage
Topic: Param 1 in Match Stage
Replies: 2
Views: 2015

Param 1 in Match Stage

Can someone please tell me what is Param 1 in Match Stage. I am aware of m and u probability, but not exactly sure what impact Param 1 has on match and what are the acceptable values for this.

I am unable to use UCERT match without supplying a value for this.

Any help is much appreciated.

Thanks!
by dsscholar
Fri Mar 06, 2009 12:06 pm
Forum: IBM<sup>®</sup> SOA Editions (Formerly RTI Services)
Topic: Diff between RPC and DOCLIT Bindings
Replies: 1
Views: 2701

Diff between RPC and DOCLIT Bindings

Can someone please let me know what is the difference between RPC and DOCLIT ?
by dsscholar
Fri Sep 26, 2008 2:12 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Error during loading rows in DB2 database
Replies: 5
Views: 2880

Error during loading rows in DB2 database

Hello, I am trying to load a file with 6000 records in DB2. The job loads 48 rows out of 6000 and throws the following warning for remaining : [IBM][CLI Driver][DB2] SQL0803N One or more values in the INSERT statement, UPDATE statement, or foreign key update caused by a DELETE statement are not vali...
by dsscholar
Tue Jun 10, 2008 6:59 am
Forum: IBM<sup>®</sup> SOA Editions (Formerly RTI Services)
Topic: Passing parameters in a RTI enabled job
Replies: 7
Views: 5084

Making the right decision here involves understanding the various topologies availabe in an RTI or WISD Job..... Job parameters can indeed be passed into an RTI or WISD enabled Job, as input for the SOAP or SOA client, but only when the job does NOT have a WISD input. Then the Job will be invoked o...
by dsscholar
Mon Jun 09, 2008 2:08 pm
Forum: IBM<sup>®</sup> SOA Editions (Formerly RTI Services)
Topic: Passing parameters in a RTI enabled job
Replies: 7
Views: 5084

Re: Passing parameters in a RTI enabled job

Is it possible to pass the value that the user provides through WISD Input Stage to some global variable that can be used anywhere in the job ? Thanks ! How about the User Variable stage? This will allow you to use the variable anywhere within that sequence job. Thanks for your response ! But I thi...
by dsscholar
Mon Jun 09, 2008 1:32 pm
Forum: IBM<sup>®</sup> SOA Editions (Formerly RTI Services)
Topic: Passing parameters in a RTI enabled job
Replies: 7
Views: 5084

Passing parameters in a RTI enabled job

I have developed a parallel job and made it RTI enabled using WISD input and output stage. I am using DB2 stages to fetch data from database. The problem is that if I dont pass any parameters to the DB2 stage huge volume of data is selected.. resulting into an abend because of space issues. I am not...
by dsscholar
Wed Jun 04, 2008 11:47 am
Forum: IBM<sup>®</sup> SOA Editions (Formerly RTI Services)
Topic: Data not being refreshed
Replies: 0
Views: 2064

Data not being refreshed

Hi, I have developed a parallel job, published it as a webservice. I am calling this webservice using a Java Screen. The java screen displays the results correctly as long as I dont make any d/b changes. If I change an value in the d/b its not displayed on the java screen unless I undeploy and re-pl...
by dsscholar
Fri May 30, 2008 11:54 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Automatically Start Master Sequencer
Replies: 3
Views: 1222

Automatically Start Master Sequencer

Hello, I have a master sequencer which calls multiple jobs. If any of the jobs fail then the master sequencer fails automatically. In all the jobs I have set the property 'Reset if required, then run' so all the jobs are automatically reset but the master sequencer remains in "aborted" sta...
by dsscholar
Thu Apr 17, 2008 10:35 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling COBOL ROUTINE from DataStage v8
Replies: 4
Views: 1590

Sorry ! I forgot to mention, we dont have MVS Edition. We need to develop parallel jobs.
by dsscholar
Thu Apr 17, 2008 10:34 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling COBOL ROUTINE from DataStage v8
Replies: 4
Views: 1590

Thanks Ray ! We are doing a POC. Our project requires us to pull data from IMS database. We can achieve this by using Classic Federation Server or/iWay Connectors, but that would require installing certain components on IMS. Since thats a long process and it might take a couple of weeks to get the p...
by dsscholar
Wed Apr 16, 2008 12:54 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling COBOL ROUTINE from DataStage v8
Replies: 4
Views: 1590

Calling COBOL ROUTINE from DataStage v8

Hello,

Is it possible to call COBOL Routines from DataStage v8 ?

Thanks !
by dsscholar
Thu Apr 03, 2008 10:32 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: iWay connectors.
Replies: 0
Views: 665

iWay connectors.

Hi, I was planning to use classic federation server to access data from IMS. Somebody suggested that Datastage can read data from IMS via the iWay connectors. Could someone please give some insight on iWAy Connectors ? How they work ? Which one is better etc .. Any response is much appreciated. Than...
by dsscholar
Mon Mar 31, 2008 7:12 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Topology for DS Installation on an Unix Machine
Replies: 5
Views: 1835

Sorry ! I didnt notice that happening ! Will take care in future.
by dsscholar
Sat Mar 29, 2008 9:01 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Topology for DS Installation on an Unix Machine
Replies: 5
Views: 1835

You choose a directory (not a symbolic link) where you want to install the DataStage engine. You also need to provide a directory that can be used temporarily during the installation process. As you create each project, you specify a directory for its location. There are defaults for all of the abo...