Search found 5 matches

by basanth
Thu Aug 09, 2007 3:40 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Siebel With DataStage
Replies: 3
Views: 2738

Re: Siebel With DataStage

Hi Guys we got this issue resolved. It was a school boys mistake. We did not get the Siebel Jar files in Binary mode. We got them ftpied again in binary mode and the BC stage started working. Thanks for viewing this post. Please add if any comments or I can mark the topic resolved. Regards Basanth :D
by basanth
Fri Jul 27, 2007 5:58 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Siebel With DataStage
Replies: 3
Views: 2738

Siebel With DataStage

Hi Guys, We have installed siebel plugin for DataStage. we were able to use the Siebel Direct Access Stage without any issues. But facing problem while using the BC stage and EIM stage. I get the following error when i hit the view data button in a BC stage. SiebelTest..Siebel_BC_PACK_0: Initialize(...
by basanth
Tue Jun 19, 2007 3:51 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Problem when running the Job Sequence
Replies: 7
Views: 5602

Hi Skumar, There is another possiblity for the occurance for this issue. In my case there was a intermittent network glitch that happens between the server and the mounts. You can check /var/adm/messages for more details what your server was doing at that moment. I got this sorted out from my networ...
by basanth
Tue Jun 19, 2007 1:46 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Sequencer Aborts Due to Error Code = -14
Replies: 23
Views: 14117

Hello Ray, After we checked these errors for a long time, we consulted the UNIX admin who inturn routed us to the network admin. The network admin suggested that this problem was evident mainly during the nightly backups which causes the unicast flooding on all the ports or the Server. So might be d...
by basanth
Mon Jun 18, 2007 8:12 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Sequencer Aborts Due to Error Code = -14
Replies: 23
Views: 14117

Hi dwuser, Even we faced this issue intermittently. And applied the patch IBM provided even that did not help. I have checked /var/adm/messages. There was a entry in the messages file when ever the sequence aborted with -14 error. The server was trying to access an automount which was failing. This ...