Search found 303 matches
- Thu Oct 16, 2008 8:47 am
- Forum: General
- Topic: User Security Administration in Version 8.0
- Replies: 3
- Views: 2024
User Security Administration in Version 8.0
Hi, IBM recently install version 8.0 in our shop (we are also running our old version 7.5). Durring the install they set up security on the OS level and all users/passwords were created within the IIS administrative console. We need to mimic how it works on 7.5 where I was able to choose groups defi...
- Mon Oct 06, 2008 1:35 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: ODBC error(for one user only)
- Replies: 4
- Views: 3260
The weird thing is that we were. Not sure why his execution was choosing the table created by his id even though the ODBC was using a process id for both of us. Developers execution: Project:CostFoundation (NJROS1BVA0301) Job name:cfsstg_plan_cost_objct_stage_2 Event #:922 Timestamp:10/6/2008 1:01:1...
- Mon Oct 06, 2008 1:20 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: ODBC error(for one user only)
- Replies: 4
- Views: 3260
Looks like we found the problem. The user who was having the problem created the same table(minus the 2 new columns that had teh errors) in the database with his id as the owner. I had him update the job to refernce dbo.table name and it seems like everything is fine now. I'll also make sure to have...
- Mon Oct 06, 2008 11:21 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: ODBC error(for one user only)
- Replies: 4
- Views: 3260
ODBC error(for one user only)
Hi, We have a job that one of the users is executin and gets the error below. When I execute, no errors at all. The SQL server connection (via ODBC) is identiacal for both of us using a process id(uid/pwd combo) defined in job parameters. Any ideas what may cause this? Thanks - - John SELECT src_id,...
- Wed Sep 17, 2008 7:24 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Trying to skip reading of header and trailer
- Replies: 5
- Views: 2651
- Tue Sep 16, 2008 3:24 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Trying to skip reading of header and trailer
- Replies: 5
- Views: 2651
They are wrapping(and really are fixed width)....I actually tried doing what you suggested Ray, by defining the whole record as VarChar and was erroring out....just realized I needed to uncheck the fixed-width for it to work. I will give it a shot and report back with the results. Thanks for all the...
- Tue Sep 16, 2008 2:41 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Trying to skip reading of header and trailer
- Replies: 5
- Views: 2651
Trying to skip reading of header and trailer
Hi, One of our jobs is receiving an input file from the mainframe(fixed with) and always has a header and trailer. In the constraint I have coded: @INROWNUM > 1 and inSeqPlanfund_hldngs.PlanNumber <> "990000" to bypass reading them.... When I run I get the following error: LoadBPASFile..se...
- Thu Sep 11, 2008 12:20 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Stopping Log entries
- Replies: 10
- Views: 4146
- Thu Sep 11, 2008 10:29 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Stopping Log entries
- Replies: 10
- Views: 4146
OK..I figured I would be patient. I just went back in Director to take a peek and recieve teh following pop-up...... Any ideas what to do with this?? Error selecting from log file RT_LOG207 Command was: SSELECT RT_LOG207 WITH @ID LIKE '1N0N' COUNT.SUP Error was: Internal data error. File 'D:\DataSta...
- Wed Sep 10, 2008 1:04 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Stopping Log entries
- Replies: 10
- Views: 4146
- Wed Sep 10, 2008 1:03 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Stopping Log entries
- Replies: 10
- Views: 4146
- Wed Sep 10, 2008 12:57 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Stopping Log entries
- Replies: 10
- Views: 4146
Stopping Log entries
Hi,
A developer has just run a job in dev with the "no Limit" for the warnings. We managed to terminate the job(by recompiling) and clear the log, but it keeps writing to it. Is there any way to stop this.......3 hours later??
Thanks for any info....
John
A developer has just run a job in dev with the "no Limit" for the warnings. We managed to terminate the job(by recompiling) and clear the log, but it keeps writing to it. Is there any way to stop this.......3 hours later??
Thanks for any info....
John
- Thu Jul 24, 2008 12:13 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: No project access
- Replies: 7
- Views: 5077
- Wed Jul 23, 2008 8:54 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: No project access
- Replies: 7
- Views: 5077
- Tue Jul 22, 2008 2:18 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: No project access
- Replies: 7
- Views: 5077
No project access
Hi, We recently installed version 8 on our windows 2003 server and I had 3 projects defined. Today we realized we installed the C++ compiler but forgot the SDK piece from Microsoft. After installing the specified SDK software and rebooting the server I can no longer access any of the projects throug...